Anritsu 68367C Synthesized High Performance Signal Generator, 10 MHz – 40 GHz

Anritsu 68367C,"High-performance signal generator delivering clean, stable signals across 10 MHz to 40 GHz. Designed for advanced microwave testing, including satellite, radar, and telecom systems. Provides exceptional frequency accuracy, low noise, and flexible output control. Suitable for automated and manual testing environments requiring precision and reliability."

Model
Anritsu 68367C
Calibration
Available on request
Price
$9,239
Status
In stock
RFQ ref
68367C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 68367C is a synthesized signal generator delivering precise, stable RF signals from 10 MHz to 40 GHz for advanced microwave test applications. It combines ultra-low phase noise, wide dynamic range output control, and sophisticated modulation capabilities - making it ideal for satellite, radar, and telecommunications system characterization. The instrument supports multiple sweep modes, complex signal generation, and flexible leveling accuracy down to –120 dBm, enabling demanding receiver sensitivity and radar blind spot testing scenarios.


Technical Specifications

Frequency Performance

  • Range: 10 MHz to 40 GHz

  • Resolution: 0.1 Hz (with Option 11) or 1 kHz standard

  • Accuracy: Within ±30 MHz or ±2 MHz (for sweep speeds ≤50 MHz/ms); tracks internal or external 10 MHz time base Output Power

  • Maximum: +17 dBm (leveled to 20 GHz)

  • Minimum: –125 dBm, –120 dBm typical with attenuator

  • Leveling Accuracy: ±0.01 dB steps to –120 dBm Phase Noise

  • SSB Phase Noise: –107 dBc/Hz at 10 kHz offset from 10 GHz Modulation Capabilities

  • Internal modes: AM, FM, Phase Modulation, Pulse Modulation, Scan Modulation

  • Waveforms: Seven standard types including Gaussian noise; user-defined arbitrary waveforms supported

  • Pulse Modulation: Doublet, triplet, quadruplet pulses; Swept Delay for moving target simulation; single and multiple pulse generation for radar recovery time testing

  • Simultaneous modulations across full frequency range Sweep Modes

  • Types: CW, step, analog, manual, and alternate sweep

  • Time range: 30 ms to 99 seconds

  • Sweep width: 1 kHz (0.1 Hz with Option 11) to full range

  • Step sweep: 1 to 10,000 steps; 1 kHz minimum step size (0.1 Hz with Option 11)

  • Step time: 1 ms to 99 seconds/step (dwell after lock); 20 ms to 99 seconds/step fixed-rate mode

  • Linear or logarithmic sweep selectable; manual stepped frequency adjustment supported


Key Features



  • Frequency resolution to 0.1 Hz with Option 11

  • Leveled power control in 0.01 dB increments for precise receiver testing

  • Up to 4 list sweep tables for complex test sequences

  • Phase-locked manual frequency stepping between limits


Typical Applications Satellite and terrestrial communications testing; radar system characterization; receiver sensitivity validation; blind spot and recovery time assessment; automated and manual RF subsystem evaluation.


Compatibility & Integration Supports external 10 MHz time base reference; accepts user-downloaded arbitrary waveforms; compatible with both automated test sequences and manual measurement workflows.

Specifications

ParameterValue
Frequency Range10 MHz to 40 GHz | Power Range (dBm): '-125 dBm to +17 dBm

Anritsu 68367C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 68367C. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 68367C faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 68367C price

This Anritsu 68367C is listed at $9,239. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 68367C calibration cost

NIST-traceable calibration for the Anritsu 68367C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents