Anritsu 69077B Ultra Low Noise Synthesized CW Generator, 0.01 – 50 GHz

Anritsu 69077B,"Ultra low noise CW generator for 0.01 to 50 GHz applications. Offers clean signals for testing high-performance RF and microwave components."

Model
Anritsu 69077B
Calibration
Available on request
Price
$31,579
Status
In stock
RFQ ref
69077B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69077B is an ultra-low noise synthesized CW generator delivering high-purity RF and microwave signals across 0.01 GHz to 50 GHz. Built on Anritsu's synthesizer technology, this instrument combines exceptional phase noise performance with wide dynamic range, making it essential for component characterization, system integration, and local oscillator applications where signal integrity is non-negotiable.


Technical Specifications

Frequency

  • Range: 0.01 GHz to 50 GHz

  • Optional extension down to 0.1 Hz

  • Resolution: 1 kHz standard; 0.1 Hz with Option 11

  • Switching time: <5 ms for steps <100 MHz; <15 ms + 1 ms/GHz or <40 ms maximum Output Power

  • Guaranteed leveled to 40 GHz: +6 dBm

  • Maximum leveled to 20 GHz: +17 dBm

  • Minimum leveled range: -15 dBm

  • With electronic attenuator: -140 dBm

  • With attenuator: -120 dBm

  • Resolution: 0.01 dB (log) or 0.001 mV (linear) Phase Noise & Spectral Purity

  • SSB phase noise: -100 dBc to -107 dBc at 10 kHz offset from 10 GHz

  • Better than -130 dBc/Hz at 1 GHz, 20 kHz offset

  • Spurious signals: -100 dBc Frequency Stability

  • Internal time base: <2×10⁻⁸/day aging; <5×10⁻¹⁰/day with Option 16

  • Temperature stability: <2×10⁻⁸/°C over 0°C; <2×10⁻¹⁰/°C with Option 16

  • Oven-stabilized oscillators: <5×10⁻¹⁰ per day


Key Features



  • Sweep modes: Digital frequency, digital power, analog, step, and alternate sweep

  • Step sweep: 1 to 10,000 steps with variable dwell time (1 ms to 99 seconds per step)

  • Modulation: Internal AM, FM, phase, and pulse modulation

  • Wide dynamic range supporting measurement of RF/microwave devices


Typical Applications



  • Local oscillator (LO) for mixers and frequency conversion

  • Component testing requiring ultra-low phase noise

  • System validation in radar, communications, and measurement systems

  • Calibration and characterization of RF networks and components


Compatibility & Integration The 69077B interfaces with swept measurement systems and integrates into test automation environments requiring phase-coherent signals with minimal spectral artifacts.

Specifications

ParameterValue
Frequency Range0.01 GHz to 50 GHz | Power Range (dBm): '-140 dBm to +17 dBm

Anritsu 69077B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69077B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69077B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69077B price

This Anritsu 69077B is listed at $31,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69077B calibration cost

NIST-traceable calibration for the Anritsu 69077B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents