Anritsu 69269A Synthesized Signal Generator, 0.01 – 40.0 GHz
Anritsu 69269A Synthesized Signal Generator,Generates signals from 0.01 to 40 GHz with high linearity and low spurious output. Optimized for defense electronics, microwave link testing, and RF design verification.
- Model
- Anritsu 69269A
- Calibration
- Available on request
- Price
- $21,530
- Status
- In stock
- RFQ ref
- 69269A
This unit
The Anritsu 69269A is a synthesized signal generator delivering phase-locked RF output across 0.01 to 40 GHz with output power spanning –125 dBm to +17 dBm in 0.01 dB steps. Built for defense electronics, microwave link testing, and RF design verification, it combines ultra-low phase noise (–100 dBc/Hz @ 10 kHz offset from 10 GHz) with flexible modulation and sweep architectures.
Technical Specifications
Frequency Coverage & Stability- Frequency range: 0.01 to 40 GHz
- Frequency resolution: 1 kHz (0.1 Hz with Option 11)
- Frequency stability with aging: < 2 × 10⁻⁸/day (< 5 × 10⁻¹⁰/day with Option 16)
- Frequency stability with temperature: < 2 × 10⁻⁸/°C over 0°C to 55°C (< 2 × 10⁻¹⁰/°C with Option 16)
- Phase noise (SSB): –100 dBc/Hz at 10 kHz offset from 10 GHz Output Power
- Maximum output power: +17 dBm
- Minimum output power: –125 dBm
- Output level resolution: 0.01 dB steps Reference & Timing
- Internal high-stability time-base (Option 16 available)
- External 10 MHz reference input accepted
- External reference output: 0.5 V p-p into 50 Ω, AC coupled, rear panel BNC connector Switching Performance
- To within 1 kHz of final frequency: < 40 ms typical maximum
- Step sweep switching: < 15 ms + 1 ms/GHz step size or < 40 ms, whichever is less
Key Features Modulation Capabilities
- Internal AM, FM, ØM, and pulse modulation
- 7 internal modulating waveforms including Gaussian noise
- User-defined arbitrary waveforms and downloadable complex modulation
- External modulation via external signal sources
- Doublet, triplet, and quadruplet pulse support for RADAR blind spot testing
- Simultaneous synchronized modulations across full frequency range Sweep Modes
- Continuous sweep: 1 MHz to full range
- Step sweep: 1 to 10,000 steps with dwell time from 1 ms to 99 seconds
- Alternate sweep mode between two ranges with independent power levels
- Manual sweep with phase-locked frequency adjustment
Typical Applications Defense electronics testing, microwave link characterization, RF component design verification, RADAR signal simulation.
Compatibility & Integration Accepts external 10 MHz reference; provides external reference output for system synchronization.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.01 to 40 GHz | Power Range (dBm): –125 dBm to +17 dBm | Voltage / Current Range: 0.5 V p-p into 50 Ω (external reference output) |
Anritsu 69269A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu 69269A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu 69269A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Anritsu 69269A price
This Anritsu 69269A is listed at $21,530. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu 69269A calibration cost
NIST-traceable calibration for the Anritsu 69269A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →