Anritsu 69363A Synthesized Sweep/Signal Generator. 2 – 40 GHz

Anritsu 69363A Synthesized Sweep/Signal Generator, 2 – 40 GHz, offers a balance of performance and affordability with essential features for microwave signal generation and testing applications.

Model
Anritsu 69363A
Calibration
Available on request
Price
$16,540
Status
In stock
RFQ ref
69363A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 69363A is a synthesized sweep/signal generator delivering microwave signal generation across 2 GHz to 40 GHz. It generates continuous wave (CW) frequencies and both broad and narrow band sweeps with phase-lock capability, supporting analog, step, manual, and alternate sweep modes. Programmable frequency agility stores up to 1000 non-sequential frequencies addressable via GPIB control.


Front-panel and remote operation (IEEE-488) control all functions except power on/standby.


Technical Specifications



  • Frequency Range: 2 GHz to 40 GHz

  • Output Power Range: -125 dBm to +17 dBm

  • Frequency Switching Time (between sweep ranges): Typically less than 40 ms

  • Step Sweep Switching Time: Typically less than 15 ms + 1 ms/GHz step size, or less than 40 ms, whichever is less

  • Dwell Time Per Step: 1 ms to 99 seconds (variable)

  • Internal Time Base Stability (aging): Typically less than 2 × 10⁻⁸/day; optional stability module reduces to < 5 × 10⁻¹⁰/day

  • Internal Time Base Stability (temperature): Typically < 2 × 10⁻⁸/°C (0°C to 55°C range)

  • Phase Noise: Ultra-low SSB phase noise characteristics typical of 69000 series instruments


Key Features



  • Synthesized CW and sweep generation across full 2–40 GHz range

  • Analog sweep for continuous frequency adjustment

  • Step sweep with user-selectable step counts and sizes

  • Manual sweep with phase-locked frequency stepping

  • Alternate sweep mode between two independent frequency ranges with configurable power levels

  • High-resolution phase-lock capability

  • Frequency agility: up to 1000 programmable non-sequential frequencies stored in volatile memory

  • External 10 MHz reference input

  • GPIB (IEEE-488) remote control interface


Typical Applications Microwave signal generation, component characterization, receiver testing, and broadband system validation across X-, Ku-, and Ka-band frequencies.


Compatibility & Integration Local front-panel operation or remote control via IEEE-488 GPIB interface. Accepts external 10 MHz reference signals for synchronized operation in multi-instrument test systems.

Specifications

ParameterValue
Frequency Range2 GHz to 40 GHz | Power Range (dBm): '-125 dBm to +17 dBm

Anritsu 69363A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 69363A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 69363A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 69363A price

This Anritsu 69363A is listed at $16,540. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 69363A calibration cost

NIST-traceable calibration for the Anritsu 69363A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →