The Keysight/Agilent/HP 83440B is a DC to 6 GHz lightwave detector that converts modulated optical signals into electrical waveforms for analysis on standard test instruments. Built around a hermetically sealed, unamplified InGaAs photodiode, the 83440B delivers high-fidelity O/E conversion with minimal signal distortion. Its direct-mount probe design connects to instrument front panels via a precision 3.5 mm microwave coaxial connector, eliminating external cable losses and coupling artifacts that degrade measurement accuracy. Engineered for telecommunications component characterization, laser performance validation, and general fiber optic measurements, the 83440B combines fast temporal response with broad bandwidth to capture both pulse shapes and spectral content in a single instrument connection.
Technical Specifications
Bandwidth: 6 GHz (3 dB optical)
Rise/Fall Time (10–90%): <80 ps
Pulse Response (FWHM): 73 ps
System Aberrations (2 ps FWHM pulse): 10% peak-to-peak maximum, 5% typical
DC Responsivity at 1300 nm: 35 V/W minimum (into 50 Ω load)
Deflection Factor at 1300 nm: 29 µW/div (Agilent 54120 family oscilloscope)
Deflection Factor at 1550 nm: 31 µW/div (Agilent 54120 family oscilloscope)
Noise Equivalent Power: 2 µW RMS maximum
Photodiode: Hermetically sealed, unamplified InGaAs
Optical Input: Universal interface, compatible with 9/125 µm fiber
Electrical Output Connector: Precision 3.5 mm microwave coaxial
Key Features
Direct-mount probe eliminates external cabling and connector losses
Low internal distortion preserves signal integrity across the full 6 GHz band
High conversion gain enables use with standard electrical instruments
Fast <80 ps rise/fall time resolves nanosecond and sub-nanosecond optical events
Option 050 includes 50 Ω termination with fourth-order Bessel-Thomson response for SDH/SONET filter compatibility
Typical Applications
Fiber optic telecommunications system characterization
Laser and optical modulator performance optimization
Optical pulse shape and timing analysis
High-speed optical signal spectral measurements
Component testing in optical communication networks
Compatibility & Integration The 83440B connects to the front panel of Agilent/Keysight electrical instruments and oscilloscopes. Its universal optical interface accommodates standard fiber connectors via optional adapters.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 6 GHz | Voltage / Current Range: 35 V/W @ 1300 nm (DC responsivity) | Wavelength Range: 1300 nm, 1550 nm |
Keysight / Agilent / HP 83440B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent / HP 83440B. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight / Agilent / HP 83440B faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.
Keysight / Agilent / HP 83440B price
This Keysight / Agilent / HP 83440B is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight / Agilent / HP 83440B calibration cost
NIST-traceable calibration for the Keysight / Agilent / HP 83440B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →