HP / Agilent 83624B High Power Swept-Signal Generator, 2 – 20 GHz,+20 dBm calibrated output
HP / Agilent RF Signal Sources. Frequency range: 2 GHz to 20 GHz, Resolution: 1 kHz standard.
- Model
- HP / Agilent 83624B
- Calibration
- Available on request
- Price
- $8,500
- Status
- In stock
- RFQ ref
- 83624B
This unit
The HP/Agilent 83624B is a synthesized swept-signal generator engineered for precision RF and microwave applications spanning 2 GHz to 20 GHz. It delivers calibrated output power to +20 dBm with exceptional spectral purity and phase noise performance. Built on the proven 8360B series architecture, this instrument combines synthesizer accuracy with analog sweep speed, making it ideal for demanding test scenarios including amplifier characterization, radar development, and complex system integration.
Technical Specifications Frequency & Output Power
Frequency range: 2 GHz to 20 GHz
Calibrated output power: +20 dBm
Maximum leveled output power: +20 dBm (83624B)
With Option 001 Step Attenuator: minimum settable output power −110 dBm
Frequency resolution: 1 kHz standard; 1 Hz with Option 008 Spectral Performance
Harmonics: typically −50 dBc below 20 GHz
Nonharmonically related spurious signals: typically −60 dBc (10 MHz to <2.0 GHz)
SSB phase noise: 20 GHz: specifications apply 0 °C to 25 °C
Maximum leveled output power at 35 °C to 55 °C: typically degrades <2 dB Sweep Capabilities
Sweep types: analog, CW, step, list, manual, ramp, alternate
Control modes: start/stop, center/span, marker (M1–M2)
Trigger: auto, external, single, or GPIB
Point capacity: 2 to 801 points per table; up to 8 tables
Switching time without attenuator change: 10 ms typical
Switching time within frequency band: 15 ms + (step size/1 GHz) × 5 ms
Key Features
Synthesized architecture with 1 kHz standard frequency resolution
Analog sweep capability for rapid system characterization
Manual, step, list, and ramp sweep modes for flexible stimulus control
GPIB integration for automated test sequences
Multiple trigger sources: auto, external, single, and bus-driven
Temperature-compensated output level accuracy across operational range
Typical Applications
Amplifier gain and linearity testing
Radar and EW system development and validation
Filter and component characterization
Receiver sensitivity and dynamic range assessment
Microwave subsystem integration and troubleshooting
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 GHz to 20 GHz | Power Range (dBm): −110 dBm to +20 dBm |
HP / Agilent 83624B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83624B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83624B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83624B price
This HP / Agilent 83624B is listed at $8,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83624B calibration cost
NIST-traceable calibration for the HP / Agilent 83624B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →