HP / Agilent 83751B High Power Synthesized Sweeper, 2 – 20 GHz
HP / Agilent RF Signal Sources. Frequency range: 2 GHz to 20 GHz.
- Model
- HP / Agilent 83751B
- Calibration
- Available on request
- Price
- $5,200
- Status
- In stock
- RFQ ref
- 83751B
This unit
The HP/Agilent 83751B is a high-power synthesized sweeper delivering precise signal generation across 2 GHz to 20 GHz. Built for RF and microwave component testing, it combines synthesized accuracy with high-speed swept performance in a benchtop instrument. The 83751B supports continuous analog and digital stepped sweeps, multiple modulation modes, and flexible output configurations, making it suitable for R&D and production test environments requiring repeatable, phase-coherent measurements.
Technical Specifications
Frequency Performance- Frequency range: 2 GHz to 20 GHz
- Output impedance: 50 ohms
- Output connector: APC-3.5mm male (standard); Type-N optional (Option 1ED); rear panel output available (Option 1E4) Output Power
- Maximum leveled power: +16 dBm (below 2 GHz), +17 dBm (2 GHz and above)
- Harmonics: −20 dBc
- With Option 1E1 step attenuator: Maximum leveled power reduced by 1 dB
- Power sweep range: 25 dB Modulation
- Pulse: 60 dB on/off ratio; 15 ns rise/fall (0.5–2 GHz), 100 ns rise/50 ns fall (2–20 GHz); internal generator 1–65 µs width and period; 2 µs minimum leveled width
- AM: 1 dB/V sensitivity, >100 kHz bandwidth (3 dB), 22 dB depth, 3.5 kohms input impedance
- FM: DC to 10 MHz rates; ±75 MHz deviation (DC–100 Hz), ±7 MHz (100 Hz–1 MHz), ±5 MHz (1–2 MHz), ±1 MHz (2–10 MHz); −6 or −20 MHz/V sensitivity; 1 kohm input impedance Sweep Modes
- Continuous wave, stepped, ramp, power, marker, and alternate sweep
- Broadband and narrowband operation Reference
- 10 MHz reference output: 0 dBm nominal, 50 ohms (BNC female, rear panel)
Key Features
- Synthesized frequency generation for superior stability and accuracy
- Internal pulse generator with 1 µs resolution
- AM depth of 22 dB; FM deviation up to ±75 MHz at low modulation rates
- Flexible sweep architecture with marker and alternate modes
- Optional step attenuator and alternative connectors
Typical Applications
- Component characterization and scalar network analysis
- Swept frequency testing of RF filters, amplifiers, and antennas
- Modulation performance validation
- Benchtop R&D and manufacturing test
Compatibility & Integration Standard 50 ohm interface; 10 MHz reference clock synchronization available via rear panel. Step attenuator option and connector variants support diverse test configurations.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 GHz to 20 GHz | Power Range (dBm): '+16 dBm to +17 dBm (maximum leveled power) |
HP / Agilent 83751B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83751B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83751B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83751B price
This HP / Agilent 83751B is listed at $5,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83751B calibration cost
NIST-traceable calibration for the HP / Agilent 83751B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →