Fluke 8400A/FM

Fluke Laboratory Measurement Instruments. Sensitivity: 1 µV, Accuracy: 0.002%.

Model
Fluke 8400A/FM
Calibration
Available on request
Price
$225
Status
In stock
RFQ ref
8400A/FM
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 8400A is a 5½-digit precision digital voltmeter engineered for systems integration and laboratory measurement applications. This benchtop instrument delivers DC voltage measurements across five ranges from ±0.1 V to ±1000 V with 1 µV sensitivity and exceptional 0.002% basic DC accuracy. The design leverages Fluke's Recirculating-Remainder A/D conversion technique to ensure high long-term accuracy, superior linearity, and reliable environmental stability.

Technical Specifications

Display: 5½ digits

DC voltage ranges: ±0.1 V to ±1000 V (five ranges)

Sensitivity: 1 µV

Basic DC accuracy: 0.002%

Common mode rejection (DC): 140 dB

Input resistance (DC, 0–500 V): Infinite at null

Input resistance (AC): 1 MΩ, 35 pF (500 V and 50 V ranges); 1 MΩ, 50 pF (5 V and 0.5 V ranges)

Conversion technique: Recirculating-Remainder A/D

Weight: 16 lbs

Key Features

Standard cell reference; optional Zener diode reference (AG suffix)

Benchtop form factor with compact footprint

Systems-oriented architecture for measurement system integration

Optional remote control and printer output

Optional low-capacity probe for specialized measurements

Compatibility & Integration The 8400A integrates into larger measurement systems via optional remote control and data output capabilities. Rack-mounting kits - including the 881A-103 dual mounting kit and 881A-102 single mounting kit - enable vertical integration into standard 19-inch racks. Multiple optional add-ons expand functionality based on application-specific requirements.

Specifications

ParameterValue
Voltage / Current Range±0.1 V to ±1000 V (five ranges)

Fluke 8400A/FM — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 8400A/FM. Calibration covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 8400A/FM faults: vacuum gauge filament failure (ionization gauges), spectrophotometer D2 lamp end-of-life, wavelength motor failure, strain indicator front-panel binding post corrosion, pH electrode conditioning failure. Most specialty laboratory instruments fail at their electromechanical interfaces first — vacuum gauge connectors and filament assemblies, spectrophotometer lamp housings and motor drives, strain indicator binding post corrosion. Component-level repair is standard; manufacturer support for legacy instruments is often limited, making third-party bench repair the practical path.

Fluke 8400A/FM price

This Fluke 8400A/FM is listed at $225. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 8400A/FM calibration cost

NIST-traceable calibration for the Fluke 8400A/FM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers calibration scope varies by instrument type: vacuum gauges are verified at multiple pressure points against NIST-traceable pressure standards; spectrophotometers at wavelength accuracy and photometric accuracy points; strain gauge indicators at bridge excitation accuracy and full-scale output accuracy; pH meters against certified buffer solutions at pH 4, 7, and 10.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents