LeCroy 9310AM Dual 400MHz Oscilloscope, 100MS/s

Lecroy Digital Oscilloscopes. Bandwidth: DC to 400 MHz @ 50 Ω, Sample Rate: 100 MS/s simultaneous per channel, Sensitivity: 2 mV/div to 5 V/div.

Model
Lecroy 9310AM
Calibration
Available on request
Price
$2,479
Status
In stock
RFQ ref
9310AM
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The LeCroy 9310AM is a dual-channel digital oscilloscope engineered for high-speed signal acquisition and waveform analysis. Operating at 400 MHz bandwidth with simultaneous 100 MS/s sampling across both channels, it captures up to 200k points per channel for detailed signal characterization. The instrument delivers 8-bit vertical resolution, ±2% DC accuracy, and flexible sensitivity from 2 mV/div to 5 V/div across dual independent digitizers.


Technical Specifications

Acquisition System

  • Bandwidth: DC to 400 MHz @ 50 Ω; 350 MHz below 200 mV/div; 300 MHz at 2 mV/div; DC to 250 MHz typical @ 1 MΩ

  • Sample Rate: 100 MS/s simultaneous per channel

  • Memory: 200k points per channel

  • Sensitivity: 2 mV/div to 5 V/div, fully variable

  • Vertical Resolution: 8 bits

  • DC Accuracy: ≤ ±2% full scale

  • Input Coupling: AC, DC, GND

  • Maximum Input: 250 V (1 MΩ); ±5 V DC @ 50 Ω

  • Bandwidth Limiter: 30 MHz Time Base System

  • Time/Div Range: 1 ns/div to 1000 s/div

  • Clock Accuracy: ≤ ±0.002%

  • Interpolator Resolution: 10 ps

  • External Clock: ≤100 MHz (ECL, TTL, zero crossing) Trigger System

  • Modes: Normal, Auto, Single, Stop

  • Sources: CH1, CH2, Line, Ext, Ext/10

  • Trigger Slopes: Positive, Negative, Window (BiSlope)

  • SMART Modes: Glitch, Window, Dropout Display

  • CRT: 12.5 × 17.5 cm (9" diagonal)

  • Resolution: 810 × 696 points

  • Display Modes: YT, XY, both together

  • Vertical Zoom: 5× expansion (50× with averaging) Memory & Storage

  • Waveform Memory: Four 16-bit channels (M1–M4)

  • Processing Memory: Four 16-bit channels (A–D)

  • Setup Memory: Four non-volatile slots

  • Storage: DOS floppy, PCMCIA hard drive, memory card

  • Output: GPIB, RS-232-C, Centronics printers/plotters


Key Features



  • Dual independent acquisition paths with simultaneous sampling

  • Configurable probe attenuation and offset ranges up to ±24 V

  • Four timebase zoom traces for multi-scale analysis

  • Setup memory preserves instrument configuration across power cycles

  • Optional waveform processing including FFT and 11-bit enhanced resolution


Typical Applications



  • High-speed digital signal troubleshooting

  • Analog circuit characterization

  • Multi-channel signal correlation

  • Time-domain waveform capture and archival


Compatibility & Integration GPIB and RS-232-C interfaces enable remote control and automated data transfer. PCMCIA and floppy storage support DOS-compatible file interchange. Optional internal graphics printer provides hardcopy output without external peripherals.

Specifications

ParameterValue
Frequency RangeDC to 400 MHz | Voltage / Current Range: ±5 V DC (50 Ω), 2 mV/div to 5 V/div
Maximum Input250 V (1 MΩ)

Lecroy 9310AM — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lecroy 9310AM. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lecroy 9310AM price

This Lecroy 9310AM is listed at $2,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lecroy 9310AM calibration cost

NIST-traceable calibration for the Lecroy 9310AM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →