Fluke PM 3370A Autoranging CombiScope, 60 MHz, 2-Channel
The Fluke PM 3370A CombiScope is a 60 MHz, 2-channel autoranging oscilloscope. It combines the features of a digital storage oscilloscope and an analog oscilloscope in one unit. Ideal for a wide range of electronic testing and troubleshooting applications.
- Model
- Fluke PM 3370A
- Calibration
- Available on request
- Price
- $680
- Status
- In stock
- RFQ ref
- PM 3370A
This unit
The Fluke PM 3370A is a 60 MHz, 2-channel hybrid oscilloscope combining digital storage and analog measurement modes in a single instrument. Designed for electronics troubleshooting, signal analysis, and laboratory testing, it delivers 8-bit vertical resolution with sampling rates up to 20 MS/s per channel (interleaved) or 10 MS/s simultaneous. The autoranging capability automatically optimizes vertical and horizontal scales for clear waveform display across diverse test scenarios.
Technical Specifications
Oscilloscope Performance- Bandwidth: 60 MHz
- Channels: 2
- Vertical resolution (DSO): 8-bit
- Sampling rate: Up to 20 MS/s per channel (interleaved), 10 MS/s per channel (simultaneous)
- Record length: Up to 1024 points per channel
- Vertical sensitivity: 2 mV/div to 10 V/div (manual ranging)
- Vertical accuracy: ±3% of full scale
- Input impedance: 1 MΩ ±2% || 15 pF ±5 pF
- Maximum input voltage: 400 V (DC + peak AC) CAT II
- Trigger accuracy: ±1 div
- Timebase accuracy: ±0.005% ±50 ppm
- Sweep speed (analog): 0.5 s/div to 50 ns/div Display
- CRT display, 8 × 10 divisions
- Illuminated internal graticule
- Voltage and time cursors Power
- Input: 100–240 VAC ±10%, 50/60 Hz
- Consumption: Typically under 50 W
Key Features
- Dual-mode operation (DSO and analog)
- Input coupling: AC, DC, GND
- Trigger modes: Auto, Normal, Single Shot, Roll Mode
- Trigger types: Edge, Pulse Width, Video, Pattern
- Delayed sweep capability
- Waveform save/recall (DSO mode)
- Built-in self-test diagnostics
- Front panel rotary knobs and function buttons
Typical Applications Electronics repair and troubleshooting, real-time signal observation, educational laboratories, waveform analysis, and field service work requiring portable 2-channel measurement capability.
Compatibility & Integration Accepts standard passive oscilloscope probes (1×, 10× attenuation). Probe compensation output provided for calibration.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 60 MHz | Voltage / Current Range: 100-240 VAC input |
Fluke PM 3370A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke PM 3370A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke PM 3370A price
This Fluke PM 3370A is listed at $680. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke PM 3370A calibration cost
NIST-traceable calibration for the Fluke PM 3370A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →