Yokogawa AQ6377 1900-5500nm Optical Spectrum Analyzer
Yokogawa Optical Spectrum Analyzers. Resolution: 0.2 nm to 5 nm (selectable), Accuracy: ±0.5 nm.
- Model
- Yokogawa AQ6377
- Calibration
- Available on request
- Price
- $68,730
- Status
- In stock
- RFQ ref
- AQ6377
This unit
The Yokogawa AQ6377 is a optical spectrum analyzer for precise characterization across the 1900–5500 nm wavelength range. Using dispersive spectroscopy, it delivers measurements from –60 dBm to +13 dBm with 50 dB close-in dynamic range and wavelength accuracy of ±0.5 nm. The instrument features a free-space optical input for high coupling efficiency and maintenance-free operation, an integrated gas purge system to suppress water vapor absorption, and a built-in cut filter that removes high-order diffraction below 1500 nm.
Wavelength resolution spans 0.2 nm to 5 nm across selectable display modes: wavelength (nm), frequency (THz), or wave number (cm⁻¹). Applications include environmental sensing, medical diagnostics, gas analysis, quantum cascade laser characterization, and advanced photonic research.
Technical Specifications
- Wavelength Range: 1900 nm to 5500 nm
- Wavelength Resolution: 0.2 nm to 5 nm (selectable)
- Wavelength Accuracy: ±0.5 nm
- Level Range: –60 dBm to +13 dBm
- Dynamic Range (Close-in): 50 dB
- Horizontal Scale Modes: Wavelength (nm), Frequency (THz), Wave Number (cm⁻¹)
- Wavelength Reference: Integrated acetylene absorption calibration with 0.6 picometer precision
Key Features
- Free-Space Optical Input: Eliminates internal fiber maintenance; accepts both single-mode and multi-mode fibers with /PC or /APC connectors
- Double Speed Mode: Increases sweep speed up to 2× standard rate with 2 dB sensitivity penalty
- Gas Purge System: Nitrogen purging through dedicated ports reduces atmospheric water vapor effects
- Cut Filter: Suppresses incoming light below 1500 nm to eliminate high-order diffracted light
- Level Fluctuation Measurement: Tracks intensity variations over time at specific wavelengths for optical alignment and stability assessment
- Built-in Calibration: Requires no external calibration equipment
Optical Input & Integration
- Fiber-optic coupling via /PC or /APC connectors to both single-mode and multi-mode fibers
- Free-space design ensures measurement repeatability without connector-induced losses
- HIGH1–3 sensitivity modes for extended dynamic range measurements
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0 THz to 158 THz | Power Range (dBm): '-60 dBm to +13 dBm | Wavelength Range: 1900 nm to 5500 nm |