Agilent/Keysight DAQ970A

Agilent / Keysight Data Acquisition Systems (DAQ).

Model
Agilent / Keysight DAQ970A
Calibration
Available on request
Price
$6,590
Status
In stock
RFQ ref
DAQ970A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight DAQ970A is a 3-slot modular data acquisition mainframe combining a 6½-digit DMM with integrated signal conditioning and plug-in measurement modules. It delivers precision data logging and real-time analysis across up to 120 single-ended channels (60 differential) at scan rates to 450 channels/second. The system measures 12 to 14 distinct signal types - temperature via thermocouple, RTD, and thermistor; DC/AC voltage and current; 2- and 4-wire resistance; frequency and period; capacitance; diode characteristics; and direct/bridge strain - with DC voltage accuracy of 0.003% and 6½-digit resolution. A 4.3" color display provides graphical visualization, while 100k non-volatile storage and up to one million points of scanning memory enable comprehensive data capture. USB, LAN/LXI connectivity, and direct USB flash drive logging support standalone and networked deployments. Autocalibration compensates for thermal and temporal drifts; internal module calibration minimizes thermocouple reference errors. The mainframe accepts specialized switching, multiplexing, and digitization modules - including the DAQM900A 20-channel solid-state multiplexer (450 channels/sec, 120 Vrms), DAQM901A 2/4-wire multiplexer (300 V), DAQM903A relay actuator module with 20 SPDT relays (300 V), and DAQM909A 4-channel 24-bit digitizer (800 kSa/s sampling). Programming via SCPI ensures compatibility with legacy 34970A and 34972A systems. Extended resistance measurements reach 1000 MΩ; current ranges span 1 µA DC to 100 µA AC. The DAQ970A suits environmental monitoring, thermal analysis, structural testing, manufacturing QA, and multi-channel research requiring flexible signal acquisition without external conditioning.

Specifications

ParameterValue
Frequency Range2 GHz (RF multiplexer module max) | Voltage / Current Range: 120 V / 0.02 A (solid-state mux)

Agilent / Keysight DAQ970A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight DAQ970A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight DAQ970A price

This Agilent / Keysight DAQ970A is listed at $6,590. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight DAQ970A calibration cost

NIST-traceable calibration for the Agilent / Keysight DAQ970A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →