Agilent/Keysight DAQM907A
Agilent / Keysight Data Acquisition Systems (DAQ). Voltage: 42 V.
- Model
- Agilent / Keysight DAQM907A
- Calibration
- Available on request
- Price
- $1,500
- Status
- In stock
- RFQ ref
- DAQM907A
This unit
The Keysight DAQM907A is a multifunction I/O module designed for the DAQ970A and DAQ973A Data Acquisition Systems. It expands mainframe capabilities with dual 8-bit digital ports, a 26-bit gated totalizer input, and two configurable analog outputs - enabling precise control and monitoring across industrial, test, and measurement applications. All digital and event inputs support continuous alarm evaluation independent of scan cycles.
Technical Specifications
Digital Input/Output- Two 8-bit digital input ports and two 8-bit digital output ports
- Digital outputs control external devices: microwave switches, attenuators, solenoids, power relays, indicators
- Digital inputs monitor limit switches and digital bus status
- Switching voltage: 42 V
- Output current rating: 400 mA
- Simple read/write operation from front panel or bus - no handshake modes required Totalizer Input
- Gated totalizer, 100 kHz maximum frequency
- 26-bit resolution
- Counts events from photo interrupters, limit switches, Hall-effect sensors
- Maintains continuously updated total accessible via front panel or program
- Runtime to overflow: approximately 45 minutes at full speed
- TTL-threshold triggering; counts only when both terminals enabled
- Includable in scan operations Analog Outputs
- Two independent analog outputs
- ±12 V voltage mode or ±24 mA current mode per output
- 16-bit resolution
- Sources bias voltages, controls programmable power supplies, provides control setpoints
- Two dedicated sensing channels for real-time monitoring of sourced voltage or current
- Direct programming in volts or milliamps Integration
- Single earth-referenced module
- Screw terminal connectivity
- Compatible with Keysight DAQ970A and DAQ973A mainframes
- Digital, totalizer, and sensing inputs integrate into system scans
- Alarm limits continuously evaluated and logged independent of scan interval
Key Features
- Flexible digital control: 16 total I/O lines for external device switching and status monitoring
- Extended event counting: 26-bit totalizer eliminates frequent overflow in long-duration tests
- Dual-mode analog sourcing: voltage and current outputs with integrated feedback sensing
- Asynchronous alarm capture: digital and counter thresholds monitored continuously
- Expandable within DAQ system architecture for multi-module configurations
Typical Applications
- Process control and device switching in automated test systems
- Event logging from mechanical sensors and digital transducers
- Programmable voltage/current bias sourcing for component characterization
- Industrial monitoring with continuous alarm detection and data logging
Compatibility & Integration The DAQM907A integrates directly into Keysight DAQ970A and DAQ973A systems, inheriting their scanning and configuration flexibility. All inputs - digital, totalizer, and analog sensing - participate in programmed scans or operate independently for alarm monitoring.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz | Voltage / Current Range: ±12 V, ±24 mA |
Agilent / Keysight DAQM907A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight DAQM907A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight DAQM907A price
This Agilent / Keysight DAQM907A is listed at $1,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight DAQM907A calibration cost
NIST-traceable calibration for the Agilent / Keysight DAQM907A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →