Stanford Research DG645 Four-Channel Digital Delay Generator

Stanford Research Systems Signal Generators. Resolution: 5 ps, Accuracy: ±500 ps ± 10 ppm of setting, Channel: to-channel skew: <.

Model
Stanford Research Systems DG645
Calibration
Available on request
Price
$5,370
Status
In stock
RFQ ref
DG645
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Stanford Research Systems DG645 is a four-channel digital delay generator delivering precise timing signals for laboratory and integrated systems requiring meticulous synchronization. With 5 ps delay resolution, sub-25 ps typical jitter, and independent control over four output channels, the DG645 addresses demanding timing applications across physics, photonics, and materials research.


Technical Specifications

Timing Performance

  • Delay resolution: 5 ps

  • Delay accuracy: ±500 ps ± 10 ppm of setting

  • Delay range: 0 ps to 1000 s (5 ps increments)

  • Pulse width resolution: 5 ps

  • Pulse width accuracy: ±500 ps ± 10 ppm of setting

  • Pulse width range: 50 ps to 1000 s

  • Jitter (RMS): <25 ps typical

  • Channel-to-channel skew: <1 ps RMS (typ.) Output Characteristics

  • Amplitude range: 0 V to 5 V into 50 Ω load

  • Output offset: -2.5 V to +2.5 V

  • Rise/fall time: <1 ns (20% to 80%, into 50 Ω load)

  • Output impedance: 50 Ω ± 5%

  • Output connectors: 4 × BNC (delay channels), 1 × BNC (trigger output) Triggering & Control

  • Internal trigger rate: 0.01 Hz to 1 MHz

  • External trigger: TTL, NIM, ECL compatible

  • Line sync and manual trigger supported

  • Trigger jitter (input to output): <25 ps RMS for clock sources (typ.)

  • Programmable trigger holdoff

  • Control: GPIB (IEEE-488.2) and RS-232


Key Features



  • Four independent delay channels with <1 ps RMS inter-channel skew

  • Picosecond-level timing resolution and accuracy across nanosecond to kilosecond timescales

  • Multiple trigger sources - internal, external, line sync, manual - with sub-25 ps jitter

  • Variable output amplitude and DC offset for integration with diverse detection systems


Typical Applications Pump-probe spectroscopy, ultrafast photonics, time-correlated single-photon counting, synchronized data acquisition, and multi-channel timing control in laser systems and particle detectors.


Compatibility & Integration Standard 19-inch rackmount chassis. GPIB and RS-232 interfaces enable remote automation. BNC connectors support TTL, NIM, and ECL logic levels. 100/120/220/240 VAC, 50/60 Hz operation.

Specifications

ParameterValue
Frequency Range0.01 Hz to 1 MHz | Voltage / Current Range: 0 V to 5 V output amplitude

Stanford Research Systems DG645 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Stanford Research Systems DG645. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Stanford Research Systems DG645 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Stanford Research Systems DG645 price

This Stanford Research Systems DG645 is listed at $5,370. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Stanford Research Systems DG645 calibration cost

NIST-traceable calibration for the Stanford Research Systems DG645 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents