Curtiss-Wright / Systran DID48-68 48-Channel, Debounced Discrete Input IP Module

Curtiss-Wright / Systran Digital Input Board. Channels: ** 48 discrete input channels, Channel: to-channel and channel-to-ground isolation prevent.

Model
Curtiss-Wright / Systran DID48-68
Calibration
Available on request
Price
$1,100
Status
In stock
RFQ ref
DID48-68
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Curtiss-Wright/Systran DID48-68 is a 48-channel debounced discrete input IP module engineered for industrial control and digital signal monitoring applications. Integrated debouncing circuitry filters electrical noise and switch bounce to deliver clean, accurate data acquisition from discrete sensors and contact closures. Network connectivity via Ethernet enables direct integration into distributed control architectures without external signal conditioning hardware.

Technical Specifications

Channels: 48 discrete input channels

Input Type: Debounced digital inputs with integrated signal conditioning

Network Interface: Ethernet (RJ45); TCP/IP protocol suite

Application Protocols: Supports Modbus TCP, EtherNet/IP, and proprietary protocols

Input Connectors: Terminal blocks or industrial-grade connectors (configuration per module variant)

Key Features

Integrated debouncing eliminates spurious signals from switch bounce and electrical noise

Channel-to-channel and channel-to-ground isolation prevents ground loops and protects against voltage transients

IP-based architecture enables networked deployment across distributed systems

DIN rail or panel mounting options for flexible enclosure integration

Industrial-grade environmental ratings suitable for harsh operating environments

Typical Applications

Discrete sensor monitoring in automated manufacturing systems

Industrial control logic and supervisory systems

Safety-critical discrete input acquisition where signal integrity is mandatory

Networked discrete I/O consolidation in multi-site control architectures

Compatibility & Integration The module integrates directly into TCP/IP-based industrial networks. Ethernet connectivity supports standard industrial protocols including Modbus TCP and EtherNet/IP, enabling interoperability with established control platforms and SCADA systems. Discrete input voltage thresholds, input current draw per channel, and isolation voltage ratings are detailed in the product manual. Power requirements and detailed environmental specifications (operating/storage temperature, humidity) are provided in technical documentation.

Curtiss-Wright / Systran DID48-68 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Curtiss-Wright / Systran DID48-68. Calibration covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Curtiss-Wright / Systran DID48-68 faults: ESD-damaged input protection, failed driver ICs, connector pin damage. Most failures involve ESD-damaged input protection circuitry, failed logic driver ICs, or mechanical connector pin damage. Board-level component replacement is standard practice.

Curtiss-Wright / Systran DID48-68 price

This Curtiss-Wright / Systran DID48-68 is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Curtiss-Wright / Systran DID48-68 calibration cost

NIST-traceable calibration for the Curtiss-Wright / Systran DID48-68 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents