The Agilent/Keysight 54652A is a parallel I/O module engineered to extend the measurement and control capabilities of Agilent 54600 Series oscilloscopes. This interface module enables parallel data transfer and control between the oscilloscope and external instruments or systems, supporting applications that demand deterministic data acquisition or inter-device communication protocols. The module incorporates hardcopy output functionality for direct waveform documentation.


Technical Specifications



  • Parallel data transfer and control interface

  • Hardcopy output capability for waveform data

  • Physical dimensions: 12 x 10 x 8 inches

  • Weight: 10 lbs


Key Features



  • Parallel interface architecture for bidirectional data exchange

  • Direct waveform output to compatible hard-copy devices

  • Modular design for straightforward integration into existing 54600 Series systems


Typical Applications



  • External device communication and control from oscilloscope platforms

  • Automated data acquisition in parallel-connected test environments

  • Real-time waveform capture and documentation workflows

  • Multi-instrument system integration requiring synchronous data transfer


Compatibility & Integration The 54652A is purpose-designed for the Agilent 54600 Series oscilloscope family. Its parallel interface connects directly to compatible 54600 instruments, enabling immediate expansion of I/O capabilities without requiring external adapters or interface cards.

Agilent / Keysight 54652A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 54652A. Calibration covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 54652A faults: ESD-damaged input protection, failed driver ICs, connector pin damage. Most failures involve ESD-damaged input protection circuitry, failed logic driver ICs, or mechanical connector pin damage. Board-level component replacement is standard practice.

Agilent / Keysight 54652A price

This Agilent / Keysight 54652A is listed at $2,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 54652A calibration cost

NIST-traceable calibration for the Agilent / Keysight 54652A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →