Agilent / Keysight DSO9104A Oscilloscope: 1 GHz, 4 Analog

Agilent / Keysight Mixed Signal Oscilloscopes (MSO). Bandwidth: 1 GHz, Sample rate: 10 GSa/s (4-channel mode), Resolution: 8 bits (up to 12 bits with averaging).

Model
Agilent / Keysight DSO9104A
Calibration
Available on request
Price
$15,694
Status
In stock
RFQ ref
DSO9104A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight DSO9104A is a 1 GHz, 4-channel digital storage oscilloscope from the Infiniium 9000 Series, designed for signal analysis, debugging, and protocol investigation. It combines oscilloscope, logic analyzer, and protocol analyzer capabilities in a single instrument, delivering 10 GSa/s analog sampling (4-channel mode) with up to 1 Gpts memory depth per channel and advanced triggering across mixed signal domains.


Technical Specifications

Bandwidth and Sampling

  • Analog bandwidth: 1 GHz

  • Analog channels: 4

  • Analog sample rate: 10 GSa/s (4-channel mode), 20 GSa/s (2-channel mode)

  • Standard memory: 20 Mpts per channel (4-channel), 40 Mpts per channel (2-channel)

  • Upgradable memory: Up to 1 Gpts per channel (2-channel mode)

  • Rise time (10%-90%): 174 ps at 50 Ω

  • Rise time (20%-80%): 59 ps at 50 Ω Vertical Characteristics

  • Resolution: 8 bits (up to 12 bits with averaging)

  • Input impedance: 50 Ω ±2.5% or 1 MΩ ±1% (11 pF typical)

  • Sensitivity: 1 mV/div to 5 V/div (1 MΩ), 1 mV/div to 1 V/div (50 Ω)

  • Input coupling: AC (3.5 Hz), DC

  • Hardware bandwidth limit: 20 MHz (1 MΩ input only) Triggering and Display

  • Advanced triggering: Edge, glitch, runt, timeout, pattern/pulse range, state, pulse width, line, window, setup and hold, video, and serial

  • Mixed-signal triggering across time-correlated analog and digital channels

  • Display: 15" XGA LCD


Key Features



  • Four included N2873A 500 MHz passive probes

  • USB and LAN connectivity; XGA/DVI video output

  • Trig in/out synchronization ports

  • GPIB support via N4865A adapter

  • Optional integrated protocol viewers for physical layer analysis

  • Support for custom measurement development


Typical Applications Serial protocol analysis, jitter characterization, compliance testing, and mixed-signal debugging across analog and digital domains.


Compatibility & Integration Standard Keysight I/O libraries suite included. Optional protocol analysis modules and user-defined applications (e.g., N5467A) expand measurement capabilities.

Agilent / Keysight DSO9104A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight DSO9104A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight DSO9104A price

This Agilent / Keysight DSO9104A is listed at $15,694. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight DSO9104A calibration cost

NIST-traceable calibration for the Agilent / Keysight DSO9104A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents