Keysight / Agilent / HP E1430A VXI 10 MSa/s 23-bit Digitizer
The Keysight E1430A is a VXI-based, high-resolution digitizer capable of capturing signals at up to 10 MSa/s with 23-bit resolution. Ideal for precision measurement applications, it offers exceptional accuracy and dynamic range in a modular VXI format.
- Model
- Keysight / Agilent / HP E1430A
- Calibration
- Available on request
- Price
- $3,200
- Status
- In stock
- RFQ ref
- E1430A
This unit
The Keysight E1430A is a C-size VXI digitizer module delivering 10 MSa/s sampling with 23-bit resolution for precision measurement and signal analysis. This register-based, one-slot instrument combines a two-pass digitizer architecture with DSP-based real-time digital filtering, programmable gain conditioning, and large FIFO memory to capture transients, analyze spectra, digitize intermediate frequencies, and record complex waveforms across demanding applications.
Technical Specifications
Sampling Rate: 10 MSa/s maximum
Resolution: 23-bit raw
Dynamic Range: 18 bits (110 dBFS) distortion-free, spur-free dynamic range with dithering and on-the-fly distortion correction
Noise Density: −136 dBfs/Hz
Noise Figure: 15 dB
Input Impedance: 50 ohms
Input Range: +28 dBm to −32 dBm, programmable in 6 dB steps
Anti-Alias Filters: Built-in; 4 MHz maximum information bandwidth; selectable bypass for fastest rise times
Digital Filters: Multistage, programmable with decimation; bandwidths from 4 MHz to 0.24 Hz in octave steps
Digital Local Oscillator: Tunable for signal-centric filtering and unwanted signal rejection
Memory: 8 MB high-speed FIFO for transient capture and block-mode data transfer
Signal Conditioning: Flexible input signal conditioning included
Local Bus Data Transfer: 40 Mbytes/sec
Key Features
Two-pass sub-ranging digitizer architecture
Programmable gain in 6 dB steps across wide dynamic range
DSP-based real-time filtering with independently tunable digital LO
Octave-step digital filter bandwidth control for noise optimization
Large FIFO memory supporting continuous acquisition and transient recording
Standard VXI data path and high-speed Local Bus connectivity
Typical Applications
Spectrum analysis and IF digitization
Transient capture and waveform recording
High-resolution time-domain measurements
Low-noise signal conditioning and filtering
Compatibility & Integration VXI-based architecture with VXIplug&play compatibility. This product is obsolete; manuals are provided for reference only.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '+28 dBm to −32 dBm |
Keysight / Agilent / HP E1430A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent / HP E1430A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight / Agilent / HP E1430A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Keysight / Agilent / HP E1430A price
This Keysight / Agilent / HP E1430A is listed at $3,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight / Agilent / HP E1430A calibration cost
NIST-traceable calibration for the Keysight / Agilent / HP E1430A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →