DDC IAC-37001 Synchro/Resolver Module
DDC VXI Modules. Resolution: 20 or 16 bits (programmable), Accuracy: 18 arc seconds (20-bit), Resolution: 16 bits.
- Model
- DDC IAC-37001
- Calibration
- Available on request
- Price
- $2,100
- Status
- In stock
- RFQ ref
- IAC-37001
This unit
The DDC IAC-37001 is a VXI C-size register-based module that combines independent synchro/resolver angle generation and measurement in a single card. It converts synchro or resolver signals into high-resolution digital data and generates precision synchro/resolver outputs, delivering the accuracy and isolation required in aerospace and industrial control systems.
Technical Specifications Measurement Section
Resolution: 20 or 16 bits (programmable)
Accuracy: 18 arc seconds (20-bit); 36 arc seconds (16-bit)
Angular Range: 0–360 degrees
Reference Input: Transformer isolated, 11.8/26/90 V line-to-line, 360–5000 Hz, ±50° phase shift maximum, 150 kΩ minimum impedance, 500 V breakdown voltage
Signal Input: Transformer isolated, 11.8/26/90 V line-to-line, 360–5000 Hz, ±50° phase shift maximum, 150 kΩ minimum impedance, 500 V breakdown voltage Generation Section
Resolution: 16 bits
Accuracy: ±25 arc seconds (no load); ±36 arc seconds (1.5 VA load)
Angular Range: 0–360 degrees
Reference Input: Transformer isolated, 11.8/26/90 V line-to-line
Signal Output: Transformer isolated, 11.8/26/90 V line-to-line, 1.5 VA load capacity, ±3.5° phase shift maximum, ±0.15 Ω output impedance, 500 V breakdown voltage
Dynamic Rotation: Programmable clockwise or counter-clockwise angular rotation via internal data rate control
Key Features
Dual independent measurement and generation channels
Transformer isolation on all synchro/resolver interfaces
Programmable resolution (16/20-bit measurement)
Selectable voltage levels (11.8, 26, 90 V)
Mode selection: synchro or resolver operation
Internal/external rate signal configuration for dynamic rotation
Wrap-around self-test capability
Full 360° measurement and generation range
Typical Applications
Aircraft attitude and heading reference systems
Rotating machinery position feedback and control
Precision angle encoder interfaces
Synchro-to-digital conversion in legacy avionic systems
Multi-axis position simulation and test
Compatibility & Integration The IAC-37001 integrates into standard VXI C-size slot architecture. All signal inputs and outputs employ transformer isolation to prevent ground loops and ensure noise immunity in high-voltage industrial environments. Programmable self-test simplifies system validation.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 360–5000 Hz | Voltage / Current Range: 11.8/26/90 V (line-to-line) |
DDC IAC-37001 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the DDC IAC-37001. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common DDC IAC-37001 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
DDC IAC-37001 price
This DDC IAC-37001 is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
DDC IAC-37001 calibration cost
NIST-traceable calibration for the DDC IAC-37001 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →