Agilent/Keysight E4990A
Agilent / Keysight Laboratory Measurement Instruments. Accuracy: ±0.08% (typical ±0.045%), Voltage: 0 V to ±40 V, Current: 0 A to ±100 mA.
- Model
- Agilent / Keysight E4990A
- Calibration
- Available on request
- Price
- $1,879
- Status
- In stock
- RFQ ref
- E4990A
This unit
The Keysight E4990A Impedance Analyzer delivers high-precision impedance measurements across 20 Hz to 10/20/30/50/120 MHz with selectable frequency options. Built for R&D, manufacturing, and quality assurance, this instrument combines ±0.08% basic accuracy (typical ±0.045%) with flexible measurement configurations to characterize components, materials, and assemblies across impedance ranges from 25 mΩ to 40 MΩ.
Technical Specifications
Frequency Range- 20 Hz to 10, 20, 30, 50, or 120 MHz (upgradable options) Impedance Measurement
- Accuracy: ±0.08% (typical ±0.045%)
- Range: 25 mΩ to 40 MΩ (within 10% measurement accuracy)
- Parameters: |Z|, |Y|, θ, R, X, G, B, L, C, D, Q, Cp, Cs, Lp, Ls, Rp, Rs, Complex Z, Complex Y, Vac, Iac, Vdc, Idc DC Bias
- Voltage: 0 V to ±40 V, 1 mV resolution, ±[0.1% + (5 + 30 × |Imon|)] mV accuracy (typical)
- Current: 0 A to ±100 mA, 40 µA resolution, ±[2% + (0.2 + |Vmon|/20)] mA accuracy (typical) AC Signal Source
- Voltage: 5 mVrms to 1 Vrms, 1 mV resolution
- Current: 200 µArms to 20 mArms, 20 µA resolution
- Auto Level Control (ALC) maintains signal accuracy across frequency range Measurement Speed
- Option 120: 3 msec/point (fast mode, ≥100 kHz)
- Options 010/020/030/050: 30 msec/point (fast mode, ≥100 kHz)
- Enhanced speed option (Option 001) available
Key Features
- Four-terminal pair measurement standard; 7-mm 1-port via 42942A Terminal Adapter
- Impedance probe support using 42941A accessory
- 10.4-inch color LCD touch screen with 4-channel, 4-trace display
- Equivalent circuit analysis with seven multi-parameter models
- Limit line testing for go/no-go production screening
- Handler interface for automated test system integration
- Specifications warranted at 23 °C ± 5 °C after 90 minutes warm-up
Typical Applications
- Component characterization and validation
- Materials analysis and dielectric measurement
- Semiconductor device testing
- Manufacturing quality assurance
- Equivalent parameter extraction
Compatibility & Integration
- Keysight 42942A Terminal Adapter for 7-mm 1-port measurements
- Keysight 42941A impedance probe support
- Handler interface integration for production automation
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz to 120 MHz | Voltage / Current Range: 100-240 VAC, 5 mVrms to 1.0 Vrms, DC bias 0 V to ±40 V |
Agilent / Keysight E4990A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E4990A. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight E4990A faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.
Agilent / Keysight E4990A price
This Agilent / Keysight E4990A is listed at $1,879. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight E4990A calibration cost
NIST-traceable calibration for the Agilent / Keysight E4990A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →