JDS Uniphase HA9108-SPL2

JDS Uniphase Optical Attenuators. Accuracy: ** ±0.15 dB across entire range, Wavelength: dependent attenuation supports broadband optical t.

Model
JDS Uniphase HA9108-SPL2
Calibration
Available on request
Price
$650
Status
In stock
RFQ ref
HA9108-SPL2
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase HA9108-SPL2 is a programmable optical attenuator for precise control of optical signal power in multimode fiber networks. It delivers attenuation across 750–1700 nm with variable range depending on wavelength band, ±0.15 dB accuracy, and remote control via GPIB or RS232. Designed for telecommunications and data center applications where signal integrity and repeatable attenuation are critical.

Technical Specifications

Fiber Type: Multimode 62.5/125 µm

Operating Wavelength Range: 750–1700 nm

Attenuation Range: 100 dB (750–1500 nm); 60 dB (1500–1700 nm)

Attenuation Accuracy: ±0.15 dB across entire range

Insertion Loss: 40 dB

Maximum Optical Input Power: 200 mW

Connectors: ST/PC bulkhead ports (front panel); other connector types available upon request

Key Features

Front panel keypad control with real-time attenuation adjustment

GPIB (IEEE 488.2) and RS232 remote interfaces for system integration

SCPI/HP8156A compatible command set enables seamless integration with existing test platforms

Low insertion loss (40 dB) ensures minimal reflections back to the source

Wavelength-dependent attenuation supports broadband optical testing from near-IR through C-band and into L-band

Typical Applications

Optical power level control in telecommunications test benches

Data center optical link characterization and validation

Multimode fiber network attenuation simulation

Equipment performance testing under controlled signal conditions

Compatibility & Integration The HA9108-SPL2 integrates into automated test systems via GPIB or serial control. Its SCPI command syntax aligns with HP8156A instruments, reducing setup time in multi-vendor environments. Front panel control supports standalone operation for manual adjustments during development and troubleshooting.

Specifications

ParameterValue
Wavelength Range750–1700 nm

JDS Uniphase HA9108-SPL2 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase HA9108-SPL2. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase HA9108-SPL2 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase HA9108-SPL2 price

This JDS Uniphase HA9108-SPL2 is listed at $650. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase HA9108-SPL2 calibration cost

NIST-traceable calibration for the JDS Uniphase HA9108-SPL2 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →