Exfo IQS-510P-N10-G1 Intelligent Test System Control Unit with 10 Slots

Exfo Embedded Test Systems. Model: IQS-510P-N10-G1.

Model
Exfo IQS-510P-N10-G1
Calibration
Available on request
Price
$3,500
Status
In stock
RFQ ref
IQS-510P-N10-G1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Exfo IQS-510P-N10-G1 is an Intelligent Test System Control Unit designed for industrial test environments, featuring 10 module slots and built on industrial PC architecture. This platform provides centralized control and data acquisition for modular test instrumentation, with native support for remote automation and integration into complex test systems.

Technical Specifications

Processor: Industrial Pentium III

Memory: 256 MB standard (N10 designation); 512 MB available with N12 option

Operating System: Microsoft Windows 2000 Professional

Software: IQS-Manager v1.4.0.173

Module Slots: 10 single-slot positions

Operating Temperature: 0 °C to 40 °C

Storage Temperature: -40 °C to 70 °C

Relative Humidity: 0 % to 80 % non-condensing at 40 °C

Key Features Scalability & Expansion: The IQS-510P-N10-G1 scales to control up to 100 single-slot modules through integration with up to nine IQS-510E Expansion Units via EXFO Bus II interconnect. Connectivity: Standard 10/100 Base-T Ethernet and RS-232 serial interfaces enable network deployment and legacy system integration. Optional IEEE 488.2 GPIB support accommodates existing instrument ecosystems. Remote Control & Automation: Native ActiveX/DCOM and SCPI command support enables programmatic control via LabVIEW drivers or custom application development. The controller can manage other IQS-500 controllers over Ethernet networks and function as a GPIB or RS-232 system manager. Physical Options: Optional 1U rack-mountable screen/keyboard combo (GP-3005) enables space-efficient deployment in standard 19-inch racks.

Compatibility & Integration Fully compatible with IQS-510E Expansion Units and single-slot modules. Backward-compatible with IQ-200 Optical Test System modules on the IQS-500 platform. Supports LabVIEW integration via ActiveX/DCOM (remote) and ActiveX/COM (local) libraries with SCPI protocol support for vendor-neutral automation.

Exfo IQS-510P-N10-G1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Exfo IQS-510P-N10-G1. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Exfo IQS-510P-N10-G1 faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Exfo IQS-510P-N10-G1 price

This Exfo IQS-510P-N10-G1 is listed at $3,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Exfo IQS-510P-N10-G1 calibration cost

NIST-traceable calibration for the Exfo IQS-510P-N10-G1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →