Keithley KPCI-1801HC PCI Bus Data Acquisition Board
Keithley Data Acquisition Systems (DAQ). Channels: 32 differential or 64 single-ended (software confi, Resolution: 12 bits, Current: ±40 nA @ 25°C.
- Model
- Keithley KPCI-1801HC
- Calibration
- Available on request
- Price
- $550
- Status
- In stock
- RFQ ref
- KPCI-1801HC
This unit
The Keithley KPCI-1801HC is a multifunction data acquisition board for PCI bus systems. It delivers 32 differential or 64 single-ended analog input channels, 2 analog output channels, and digital I/O capabilities. Engineered for demanding measurement and control applications, it combines high-speed sampling, flexible triggering, and bus-mastering DMA to support continuous acquisition of large data volumes with minimal CPU overhead.
Technical Specifications Analog Input
Channels: 32 differential or 64 single-ended (software configurable)
Resolution: 12 bits
Throughput: 333 kS/s single channel; 312.5 kS/s aggregate multichannel
Conversion rate range: 4.32 samples/hour to 333 kS/s
Input range: Software selectable via channel gain queue
Programmable gains: 1, 5, 50, 250
Input impedance: >100 MΩ || ≤90 pF (all gains)
Input overvoltage protection: ±15 V continuous (powered or unpowered)
Input bias current: ±40 nA @ 25°C; ±60 nA over operating range
Linearity: ±1 LSB integral maximum
A/D FIFO buffer: 2048 samples
Channel gain queue: 64 entries Analog Output
Channels: 2
Resolution: 12 bits
Output range: ±10 V
Accuracy: ±5 mV typical (high impedance)
Output impedance: 4 Ω
Output current: ±5 mA maximum
Maximum capacitive load: 100 µF
D/A FIFO buffer: 16 samples Data Acquisition
Transfer modes: DMA (bus master), interrupt, polled
Triggering: Pre-trigger, post-trigger, about-trigger; external hardware trigger and gate inputs
Clocking: External pacer clock or onboard time base
Burst mode: Programmable acquisition with configurable intervals
Key Features
32-bit bus-mastering DMA for continuous large-volume data acquisition
Multiple 37-pin D-type male connectors for external accessory integration
High input impedance (>100 MΩ) minimizes loading effects
Programmable gains support signal conditioning across wide dynamic ranges
Flexible triggering and clocking enable synchronized multichannel measurements
Typical Applications Process monitoring, transient capture, multichannel signal analysis, industrial control, and laboratory measurement systems requiring simultaneous analog sampling with digital synchronization.
Compatibility & Integration PCI bus interface. Compatible with DriverLINX software; refer to DriverLINX documentation for KPCI-1800 Series configuration.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±10 V output |
Keithley KPCI-1801HC — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley KPCI-1801HC. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Keithley KPCI-1801HC price
This Keithley KPCI-1801HC is listed at $550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley KPCI-1801HC calibration cost
NIST-traceable calibration for the Keithley KPCI-1801HC is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →