Anritsu MS96A – Optical Spectrum Analyzer
Anritsu Optical Spectrum Analyzers. Resolution: 0.1 nm, Wavelength: division multiplexed systems.
- Model
- Anritsu MS96A
- Calibration
- Available on request
- Price
- $1,200
- Status
- In stock
- RFQ ref
- MS96A
This unit
The Anritsu MS96A is a optical spectrum analyzer engineered for precise spectral analysis across the visible to near-infrared spectrum. It delivers accurate characterization of light sources, optical device performance evaluation, and WDM system waveform analysis in communications, research, and development environments.
Technical Specifications
- Wavelength Range: 0.6 µm to 1.75 µm (600 nm to 1750 nm)
- Wavelength Resolution: 0.1 nm
Key Features
- Broad wavelength coverage spanning visible through near-infrared bands
- Fine spectral resolution for precise optical signal characterization
- Suitable for loss wavelength measurement in optical components
- Enables detailed analysis of wavelength-division multiplexed systems
Typical Applications
- Light source evaluation and characterization
- Optical device performance analysis
- WDM system waveform analysis
- Spectral measurement in optical communication systems
- Loss wavelength characteristic measurement
Compatibility & Integration The MS96A represents a predecessor to the MS9710A platform, providing continuity for legacy system integration and established measurement workflows.
Specifications
| Parameter | Value |
|---|---|
| Wavelength Range | 0.6 µm to 1.75 µm (600 nm to 1750 nm) |
Frequently Asked Questions
- What does the Anritsu MS96A measure and what wavelength range does it cover?
- The Anritsu MS96A is an optical spectrum analyzer designed to measure and analyze optical signals across wavelength division multiplexed (WDM) systems. It operates across a wavelength range of 0.6 µm to 1.75 µm (600 nm to 1750 nm) with a resolution of 0.1 nm, making it suitable for characterizing DWDM and CWDM channels, monitoring signal power, and detecting spectral anomalies in fiber-optic networks.
- What is the condition of this used Anritsu MS96A, and what has been verified?
- This MS96A unit is offered in used condition and has been inspected and cataloged by our team at Aumictech. We verify functional operation and mechanical integrity before listing; however, we recommend obtaining calibration certification if traceability to NIST standards is required for your application.
- Is calibration available for the MS96A, and what is the cost?
- Yes, calibration services are available separately for this instrument, starting at $450. Calibration typically covers the wavelength accuracy and optical power measurement functions across the MS96A's operating range and provides traceable certification for metrology-critical applications.
- What interfaces and connectivity options does the MS96A have?
- The Anritsu MS96A features GPIB (IEEE 488) connectivity for remote instrument control and data acquisition, enabling integration into automated test systems and software environments. We recommend verifying driver availability and software compatibility with your current test platform before purchase.
Anritsu MS96A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS96A. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu MS96A faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Anritsu MS96A price
This Anritsu MS96A is listed at $1,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS96A calibration cost
NIST-traceable calibration for the Anritsu MS96A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →