Agilent/Keysight N4985A

Agilent / Keysight RF Amplifiers. Frequency Range: 10 MHz to 50 GHz (model-dependent: N4985A-P15 10 MHz–50 GHz; N4985A-P25 2 GHz–50 GHz; N4985A-S30 100 kHz–30 GHz; N4985A-S50 100 kHz–50 GHz), Power Range (dBm): 22 dBm @ 50 GHz; >20 dBm across range; 30 dBm Psat to 10 GHz; 26 dBm P₋₁dB, 29 dBm Psat @ 20 GHz, Voltage / Current Range: Standard AC power supply.

Model
Agilent / Keysight N4985A
Calibration
Available on request
Price
$19,500
Status
In stock
RFQ ref
N4985A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight N4985A series comprises broadband system amplifiers engineered for RF and microwave applications spanning baseband to millimeter-wave frequencies. Each model delivers high gain and output power across its designated frequency range, with self-contained construction powered by standard AC mains. The series accommodates diverse test scenarios: bench-top laboratory characterization, production-line validation, and time/frequency-domain measurements.


Multiple variants

N4985A-P15, N4985A-P25, N4985A-S30, and N4985A-S50 - provide tailored frequency coverage and performance metrics for specific amplification requirements.


Technical Specifications



  • Frequency Coverage (model-dependent):


N4985A-P15: 10 MHz to 50 GHz


N4985A-P25: 2 GHz to 50 GHz


N4985A-S30: 100 kHz to 30 GHz


N4985A-S50: 100 kHz to 50 GHz



  • Gain: Up to 27 dB at 20 GHz (N4985A-P15, ±2 dB flatness); 30 dB gain to 26 GHz across series variants

  • Output Power: - 22 dBm at 50 GHz


Greater than 20 dBm across frequency range - 1 W (30 dBm) Psat to 10 GHz - 26 dBm P₋₁dB and 29 dBm Psat at 20 GHz


Key Features



  • Built-in bias power supplies eliminate external supply dependencies

  • Compact form factor enables close placement to device under test or fixture

  • Self-contained design integrates into existing benchtop or automated test setups


Typical Applications



  • Saturated RF amplifier characterization

  • Traveling Wave Tube (TWT) amplifier drive stages

  • Antenna system amplification and R&D

  • RF source amplification and mixer local oscillator chains

  • Noise figure measurement (LNA and full-system configurations)

  • Pulse and time-domain amplification

  • Digital communication system validation

  • General-purpose RF gain blocks


Compatibility & Integration Optional optical application tuning modules


N4985A-OA3 (S30 option) and N4985A-OA5 (S50 option) - extend flexibility for specialized measurement environments. Standard AC power connection ensures straightforward deployment in laboratory and production facilities.

Specifications

ParameterValue
Frequency Range10 MHz–50 GHz, 100 kHz to 50 GHz (variant dependent: 100 kHz–30 GHz, 100 kHz–50 GHz, 2 GHz–50 GHz) | Power Range (dBm): 30 dBm Psat (to 10 GHz)
22 dBm (50 GHz) | Voltage / Current Range9 V @ 1.5 A (N4985A-P25)

Agilent / Keysight N4985A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight N4985A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight N4985A price

This Agilent / Keysight N4985A is listed at $19,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight N4985A calibration cost

NIST-traceable calibration for the Agilent / Keysight N4985A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →