Ixia NOVUS10/1GE16DP

Ixia Embedded Test Systems. Model: NOVUS10/1GE16DP.

Model
Ixia NOVUS10/1GE16DP
Calibration
Available on request
Price
$18,500
Status
In stock
RFQ ref
NOVUS10/1GE16DP
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Ixia NOVUS10/1GE16DP is a high-density Layer 2-7 network and application testing load module delivering 16 Dual-PHY ports per module. Each port operates at 10 Gigabit Ethernet (10GbE), 1 Gigabit Ethernet (1GbE), or 100 Megabit Ethernet (100MbE) across both fiber (SFP+) and copper (10GBASE-T RJ45) interfaces simultaneously. The module generates full line-rate L2/3 traffic and true L4-7 application traffic with stateful generation up to 480 Gbps in a 12-slot chassis configuration.

Technical Specifications

Port Density: 16 Dual-PHY ports per module

Supported Speeds: 10 Gigabit Ethernet (10GbE), 1 Gigabit Ethernet (1GbE), 100 Megabit Ethernet (100MbE)

Interface Types: SFP+ (fiber), 10GBASE-T RJ45 (copper)

Maximum Density: Up to 192 x 10GbE/1GbE/100MbE Ethernet test ports in a single 12-slot XGS chassis

Stateful Traffic Generation: Up to 480 Gbps in a 12-slot chassis

Stateless Traffic Emulation: Up to 160 Gbps per Novus ONE appliance

Stateful Application Traffic Emulation: Up to 20 Gbps per Novus ONE appliance

Real-Time Latency Measurement: Resolution down to 2.5 ns

Key Features

Dual-PHY capability enables simultaneous testing of SFP+ and 10GBASE-T RJ45 ports at different speeds on the same module

Hardware packet capture and decode with extensive port statistics

Advanced sequence checking for protocol validation

Full line-rate traffic generation and analysis at L2/3

True L4-7 application traffic generation with subscriber emulation

Support for voice, video, storage, and access protocols

Protocol Emulation

routing and bridging protocol emulation

Routing, switching, MPLS, IP multicast, and Carrier Ethernet protocols

Data center Ethernet protocol emulation

IxLoad L4-7 support including voice, video, and access protocols

Quality of Experience (QoE) subscriber and protocol emulation

Typical Applications

ASIC design and FPGA validation

Hardware switch fabric evaluation

Data center test scenarios

Routing and switching validation

Application performance testing across L2-7

Compatibility & Integration Installs in Keysight XGS series chassis: XGS12-SD, XGS12-HSL, XGS2-SD, XGS2-HSL, XGS2-SDL, and XGS12-SDL. Integrates with Keysight IxNetwork and IxLoad for protocol emulation and application traffic generation.

Ixia NOVUS10/1GE16DP — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Ixia NOVUS10/1GE16DP. Calibration covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Ixia NOVUS10/1GE16DP faults: power supply failure (cRIO-9073/9074), C-series slot connector wear, PXI chassis fan failure, GPIB interface failure on VXI controllers, BIOS/EEPROM corruption. NI CompactRIO most common faults are power supply failure on older cRIO-9073/9074 chassis and C-series module slot connector wear from repeated hot-swap cycles. PXI chassis fan failure is the most common wear item — chassis fans are field-replaceable. VXI embedded controllers most commonly develop EEPROM corruption and GPIB interface failure.

Ixia NOVUS10/1GE16DP price

This Ixia NOVUS10/1GE16DP is listed at $18,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Ixia NOVUS10/1GE16DP calibration cost

NIST-traceable calibration for the Ixia NOVUS10/1GE16DP is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers analog input channel accuracy and offset at all gain settings, analog output accuracy, digital I/O logic threshold verification, sample rate and timing accuracy, and trigger and synchronization bus functional verification. NI CompactRIO and PXI chassis also undergo backplane trigger line integrity check.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents