JDS Uniphase OLP-55
The JDS Uniphase OLP-55 is a handheld optical power meter designed for accurate and reliable measurement of optical power in fiber optic networks. It features a wide dynamic range, high accuracy, and a user-friendly interface, making it suitable for field testing, installation, and maintenance of fiber optic systems. The OLP-55 supports various connector types and offers multiple wavelength calibration points for precise measurements.
- Model
- JDS Uniphase OLP-55
- Calibration
- Available on request
- Price
- $850
- Status
- In stock
- RFQ ref
- OLP-55
This unit
The JDS Uniphase OLP-55 is a handheld optical power meter for field installation, testing, and maintenance of fiber optic networks. It delivers precise measurements across singlemode and multimode systems using an InGaAs detector with auto-zeroing and dark current compensation. The instrument measures optical power from –60 dBm to +26 dBm across 800 nm to 1700 nm, with calibrated wavelengths at 850 nm, 1310 nm, 1550 nm, and 1625 nm. An auto-lambda function identifies wavelength automatically, eliminating manual setup errors and accelerating field testing. The OLP-55 supports simultaneous multi-wavelength measurements via TWINtest and TRIPLEtest modes, with an illuminated graphical display (128 × 64 dots) showing up to three results at once. Internal memory stores 1000 timestamped measurements; unlimited storage extends via USB memory sticks or host USB data storage. A reflection trap minimizes multiple reflections between adapter and photodiode for enhanced accuracy. The meter operates on two AA batteries (alkaline or rechargeable NiMH/NiCd) or via AC adapter, with automatic power-off after 20 minutes of inactivity. Universal Push-Pull adapter system accommodates 2.5 mm and 1.25 mm ferrules. The shock-proof, splash-proof design weighs approximately 500 g and measures 95 × 60 × 195 mm. USB connectivity enables remote operation, data transfer, and Excel-compatible report generation. Optional Visual Fault Locator (635 nm) is available. Available in general purpose, high sensitivity, and high power (+26 dBm) configurations.
Technical Specifications
Measurement Range: –60 dBm to +26 dBm
Detector: InGaAs diode
Wavelength Range: 800 nm to 1700 nm
Calibrated Wavelengths: 850 nm, 1310 nm, 1550 nm, 1625 nm
Maximum Wavelength Calibrations: Up to 900 calibrated wavelengths
Display: Illuminated graphical display, 128 × 64 dots
Data Storage: 1000 internal measurements with date/time stamp; USB expandable
Dimensions: 95 × 60 × 195 mm
Weight: Approximately 500 g
Key Features
Auto-zeroing eliminates manual calibration
Automatic dark current compensation
Reflection trap reduces adapter-to-photodiode reflections
Auto-lambda automatic wavelength detection
TWINtest and TRIPLEtest simultaneous multi-wavelength modes
Four power supply options: AA batteries, rechargeable cells, AC adapter, or USB
Auto power-off after 20 minutes inactivity (user-selectable)
Universal Push-Pull adapter system (2.5 mm and 1.25 mm ferrules)
USB client port for data transfer and Excel-compatible reports
Optional 635 nm Visual Fault Locator
Typical Applications
Broadband network installation and maintenance
PON (Passive Optical Network) deployment
Gigabit Ethernet system verification
Field fiber optic network testing
Compatibility & Integration
Singlemode and multimode fiber systems
USB data export and remote operation
Available in general purpose, high sensitivity, and high power configurations
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-70 dBm to +20 dBm | Wavelength Range: 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm, 850 nm |
JDS Uniphase OLP-55 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase OLP-55. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase OLP-55 faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.
JDS Uniphase OLP-55 price
This JDS Uniphase OLP-55 is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase OLP-55 calibration cost
NIST-traceable calibration for the JDS Uniphase OLP-55 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →