Exfo PM-1613 Single Channel High-Speed Power Meter

The Exfo PM-1613 is a single-channel, high-speed power meter designed for accurate measurement of optical power in fiber optic systems. It offers high sensitivity and fast response times, making it suitable for testing and characterization of optical components and networks.

Model
Exfo PM-1613
Calibration
Available on request
Price
$1,200
Status
In stock
RFQ ref
PM-1613
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The EXFO PM-1613 is a single-channel, high-speed optical power meter engineered for precision measurements in fiber optic systems testing and manufacturing environments. Built around a 1 mm InGaAs detector, it delivers rapid response times and high sensitivity across the 800–1700 nm wavelength band, with measurement resolution to 0.001 dB and absolute uncertainty of ±5 % over its core dynamic range. The instrument supports multiple measurement units (dB, dBm, Watt) and operates in both continuous and burst acquisition modes, sampling up to 4096 samples/second for transient capture and analysis.

Technical Specifications

Detector: Single InGaAs channel, 1 mm active area

Wavelength Range: 800–1700 nm

Power Range: −85 to 9 dBm

Power Resolution: 0.001 dB (9 dBm to −40 dBm)

Absolute Uncertainty: ±5 % (0 dBm to −55 dBm)

Linearity: ±0.015 dB (0 dBm to −55 dBm)

Noise (Peak-to-Peak): 3 pW

Sampling Rate: Up to 4096 samples/second (fast/burst mode); up to 256 samples/second (continuous)

Stabilization Time: 12 ms (automatic gain range mode, up to 95 dB fluctuations); <1 ms (manual range, locked gain)

Programmable Acquisitions: Up to 1024 samples

Operating Temperature: 0–40 °C

Key Features

Analog output and external trigger support for system integration

GPIB interface for remote instrument control and data logging

Automatic or manual gain range selection with millisecond-level response

Front-panel controls for nulling, unit selection, wavelength entry, and gain scaling

Wavelength-dependent calibration factors applicable across the measurement band

Typical Applications

Fiber optic component characterization and loss measurement

High-speed transient power monitoring and burst analysis

Manufacturing test and quality assurance workflows

Laboratory power budget validation and system commissioning

Compatibility & Integration The PM-1613 accepts interchangeable fiber-optic adapters (FOA) for various connector types, sold separately. Standard options include SMA 906, FC, DIN 47256, and ST configurations, all with low-reflection specifications. The instrument works with indoor use only.

Specifications

ParameterValue
Power Range (dBm)9 dBm to −80 dBm | Wavelength Range: 800 nm to 1700 nm

Exfo PM-1613 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Exfo PM-1613. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Exfo PM-1613 faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.

Exfo PM-1613 price

This Exfo PM-1613 is listed at $1,200. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Exfo PM-1613 calibration cost

NIST-traceable calibration for the Exfo PM-1613 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents