Fluke PM6306 Automatic RCL Meter 100kHz

Fluke Laboratory Measurement Instruments.

Model
Fluke PM6306
Calibration
Available on request
Price
$1,850
Status
In stock
RFQ ref
PM6306
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke PM6306 automatic RCL meter is a versatile instrument used for measuring inductance, capacitance, and resistance. With a test frequency range from 50 Hz to 100 kHz, it can accurately characterize a wide variety of components. It features automatic range selection and provides clear and stable readings. Ideal for electronics manufacturing, service, and education.

Fluke PM6306 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke PM6306. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke PM6306 faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.

Fluke PM6306 price

This Fluke PM6306 is listed at $1,850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke PM6306 calibration cost

NIST-traceable calibration for the Fluke PM6306 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →