Astronics / EADS / Talon Instruments SR192A 50MHz Digital Module

Astronics / EADS / Talon Instruments VXI Modules. Resolution: 5 ns, Channel: to-Channel Skew: 5 ns, Channels: Up to 192 single-ended per module.

Model
Astronics / EADS / Talon Instruments SR192A
Calibration
Available on request
Price
$2,600
Status
In stock
RFQ ref
SR192A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The SR192A is a double-wide VXI digital test module delivering 50 MHz data rates with 5 ns edge placement resolution for high-speed digital pattern generation and analysis. Scalable from 8 to 192 single-ended channels in 8-channel increments, it accommodates up to 12 internal 16-channel I/O modules and two SR101A timing modules per unit. The integrated high-speed data sequencer provides precise control over test patterns, UUT handshaking, timing, format, looping, and conditional testing across TTL, RS-485, ECL, LVDS, and variable voltage logic levels.

Technical Specifications

Data Rate: Up to 50 MHz

Edge Placement Resolution: 5 ns

Channel-to-Channel Skew: 5 ns

Maximum I/O Channels: Up to 192 single-ended per module

Configurable Range: 8 to 192 channels in 8-channel increments

Internal Module Capacity: Up to 12 modules × 16 channels each

Timing Module Support: Up to two SR101A modules per SR192A

Memory Depth: 128 Kbits per channel (256 Kbits in multiplexed mode)

Data Formats: Hold, RTZ, RT0, RTC

Output Drive: 50 mA source/sink

Input Thresholds: High 2.0 V, Low 0.8 V

Input Impedance: >10 kΩ

Output Impedance: 50 Ω

Short Circuit Protection: Yes

Key Features

Five-memory architecture: Stimulus, Tristate, Record, Expect, Mask

Multiple SR192A modules synchronize for up to 1,152 total I/O channels

Supports TTL, RS-485, ECL, LVDS, and variable voltage I/O

Trigger inputs from VXI TTL bus, VXI ECL bus, front-panel auxiliary, or any channel

Graphical user interface accelerates test development

LSRTAP file import capability

Visual timing and table definition tools

Typical Applications

Parallel and serial digital signal testing

Complex UUT handshaking sequences

High-speed pattern generation and capture

Mixed-logic-level test environments

Compatibility & Integration Double-wide VXI module form factor. Integrates with SR101A timing modules for synchronized multi-module configurations supporting logic standards across industrial and defense test platforms.

Specifications

ParameterValue
Frequency Range50 MHz | Voltage / Current Range: 0.8 V (low threshold), 2.0 V (high threshold), 50 mA source/sink

Astronics / EADS / Talon Instruments SR192A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Talon Instruments SR192A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / EADS / Talon Instruments SR192A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / EADS / Talon Instruments SR192A price

This Astronics / EADS / Talon Instruments SR192A is listed at $2,600. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / EADS / Talon Instruments SR192A calibration cost

NIST-traceable calibration for the Astronics / EADS / Talon Instruments SR192A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →