Astronics / EADS / Talon Instruments SR192A 50MHz Digital Module
Astronics / EADS / Talon Instruments VXI Modules. Resolution: 5 ns, Channel: to-Channel Skew: 5 ns, Channels: Up to 192 single-ended per module.
- Model
- Astronics / EADS / Talon Instruments SR192A
- Calibration
- Available on request
- Price
- $2,600
- Status
- In stock
- RFQ ref
- SR192A
This unit
The SR192A is a double-wide VXI digital test module delivering 50 MHz data rates with 5 ns edge placement resolution for high-speed digital pattern generation and analysis. Scalable from 8 to 192 single-ended channels in 8-channel increments, it accommodates up to 12 internal 16-channel I/O modules and two SR101A timing modules per unit. The integrated high-speed data sequencer provides precise control over test patterns, UUT handshaking, timing, format, looping, and conditional testing across TTL, RS-485, ECL, LVDS, and variable voltage logic levels.
Technical Specifications
Data Rate: Up to 50 MHz
Edge Placement Resolution: 5 ns
Channel-to-Channel Skew: 5 ns
Maximum I/O Channels: Up to 192 single-ended per module
Configurable Range: 8 to 192 channels in 8-channel increments
Internal Module Capacity: Up to 12 modules × 16 channels each
Timing Module Support: Up to two SR101A modules per SR192A
Memory Depth: 128 Kbits per channel (256 Kbits in multiplexed mode)
Data Formats: Hold, RTZ, RT0, RTC
Output Drive: 50 mA source/sink
Input Thresholds: High 2.0 V, Low 0.8 V
Input Impedance: >10 kΩ
Output Impedance: 50 Ω
Short Circuit Protection: Yes
Key Features
Five-memory architecture: Stimulus, Tristate, Record, Expect, Mask
Multiple SR192A modules synchronize for up to 1,152 total I/O channels
Supports TTL, RS-485, ECL, LVDS, and variable voltage I/O
Trigger inputs from VXI TTL bus, VXI ECL bus, front-panel auxiliary, or any channel
Graphical user interface accelerates test development
LSRTAP file import capability
Visual timing and table definition tools
Typical Applications
Parallel and serial digital signal testing
Complex UUT handshaking sequences
High-speed pattern generation and capture
Mixed-logic-level test environments
Compatibility & Integration Double-wide VXI module form factor. Integrates with SR101A timing modules for synchronized multi-module configurations supporting logic standards across industrial and defense test platforms.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 50 MHz | Voltage / Current Range: 0.8 V (low threshold), 2.0 V (high threshold), 50 mA source/sink |
Astronics / EADS / Talon Instruments SR192A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Talon Instruments SR192A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Astronics / EADS / Talon Instruments SR192A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Astronics / EADS / Talon Instruments SR192A price
This Astronics / EADS / Talon Instruments SR192A is listed at $2,600. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Astronics / EADS / Talon Instruments SR192A calibration cost
NIST-traceable calibration for the Astronics / EADS / Talon Instruments SR192A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →