JDS Uniphase TB9 JDSU TB9226-1SP1 Tunable Grating Filter 1460-1575nm
The JDS Uniphase TB9226-1SP1 is a tunable grating filter designed for use in optical communication systems. It operates in the 1460-1575nm wavelength range, offering precise wavelength selection and filtering. This filter is ideal for applications requiring dynamic wavelength management and signal conditioning.
- Model
- JDS Uniphase/JDSU TB9226-1SP1
- Calibration
- Available on request
- Price
- $4,830
- Status
- In stock
- RFQ ref
- TB9226-1SP1
This unit
The JDS Uniphase TB9226-1SP1 is a tunable grating filter engineered for dynamic wavelength selection and optical signal conditioning across the C-band and extended L-band. Built on diffraction grating technology, it delivers superior wavelength isolation and narrower passbands compared to Fabry-Perot and interference filter alternatives. The instrument operates as a precision spectral filter for single-mode fiber systems in laboratory and production test environments.
Technical Specifications
Wavelength Performance- Tuning Range: 1460–1575 nm
- Optimized Window: 1530–1570 nm
- -3 dB Bandwidth (FWHM): 0.25 nm (±15%)
- -20 dB Bandwidth: 0.7 nm (±15%)
- Minimum Passband Width: 0.22 nm FWHM
- Tuning Resolution: 0.01 nm
- Wavelength Accuracy: ±0.2 nm
- Repeatability: ±0.05 nm Optical Characteristics
- Insertion Loss: 45 dB
- Polarization Dependent Loss (PDL): < 0.2 dB (1530–1570 nm) Electrical & Environmental
- Input Power: 100–240 VAC, 50–60 Hz
- Warm-up Time: 1 hour (required for specification compliance) Fiber Interfaces
- Single-mode fiber input and output
- Standard Connector: ST/PC
- Optional: FC/PC, FC, or pigtailed FC/PC configurations
Key Features
- Front panel keypad control for manual tuning and configuration
- GPIB (IEEE 488) and RS232 interfaces enable integration into automated test racks and control systems
- Grating-based design provides steeper roll-off and sharper spectral isolation than competing filter architectures
- Selectable narrow passbands from 0.22–1.4 nm FWHM accommodate diverse wavelength-selective requirements
Typical Applications
- Amplified spontaneous emission (ASE) suppression in EDFA systems
- Spontaneous emission filtering from distributed feedback and tunable laser sources
- Wavelength-selective component characterization in WDM and DWDM test benches
- Tunable laser source validation and performance measurement
Compatibility & Integration Fully compliant with CE, UL3101-1, and CAN/CSA-C22.2 No. 1010.1 safety standards. Dual control via local keypad or remote command interfaces supports both standalone measurement and integrated automated test environments.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 100–240 VAC, 50–60 Hz | Wavelength Range: 1460–1575 nm |
JDS Uniphase/JDSU TB9226-1SP1 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU TB9226-1SP1. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common JDS Uniphase/JDSU TB9226-1SP1 faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
JDS Uniphase/JDSU TB9226-1SP1 price
This JDS Uniphase/JDSU TB9226-1SP1 is listed at $4,830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
JDS Uniphase/JDSU TB9226-1SP1 calibration cost
NIST-traceable calibration for the JDS Uniphase/JDSU TB9226-1SP1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →