JDS Uniphase TB9 JDSU TB9226-FA Tunable Grating Filter 1460-1575nm

JDS Uniphase/JDSU Optical Attenuators. Resolution: 0.01 nm, Accuracy: 0.2 nm, Wavelength: selective component testing.

Model
JDS Uniphase/JDSU TB9226-FA
Calibration
Available on request
Price
$4,830
Status
In stock
RFQ ref
TB9226-FA
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase TB9226-FA is a tunable grating filter engineered for precise wavelength selection across the S + C bands (1460–1575 nm). It delivers narrow-bandwidth optical filtering with grating-based rejection suitable for laboratory and production test environments where signal conditioning and wavelength selectivity are critical. This filter excels at ASE suppression in EDFA systems and removing spontaneous emissions from DFB and tunable laser sources during component characterization.


Wavelength tuning resolves to 0.01 nm with 0.2 nm setting accuracy and 0.05 nm repeatability. Narrow passband performance - 0.25 nm at −3 dB (FWHM) and 0.7 nm at −20 dB - enables high spectral purity across the tuning range.


Technical Specifications



  • Wavelength Tuning Range: 1460–1575 nm

  • Bandwidth (−3 dB FWHM): 0.25 nm typical (as low as 0.22 nm)

  • Bandwidth (−20 dB): 0.7 nm typical

  • Insertion Loss: ≤6.0 dB

  • Polarization Dependent Loss (PDL): ≤0.2 dB

  • Return Loss: >45 dB

  • Wavelength Resolution: 0.01 nm

  • Wavelength Setting Accuracy: 0.2 nm

  • Repeatability: 0.05 nm

  • Optical Connectors: FC/APC (SMF in/out; FC/PC available on request)

  • Input Power: 100–240 V AC, 50–60 Hz

  • Power Consumption: 80 VA maximum

  • Dimensions: 21.2 cm W × 8.9 cm H × 35.5 cm D (19 in rack mount, 2U, 1/2 rack width)

  • Weight: 4 kg

  • Operating Temperature: 10–40 °C

  • Storage Temperature: 0–50 °C


Key Features



  • Dual control via front-panel keypad and remote interfaces (GPIB/IEEE 488, RS-232)

  • Tunable grating mechanism for flexible wavelength selection across 115 nm span

  • Sub-0.25 nm passband width minimizes adjacent-channel interference

  • High return loss and low PDL ensure stable performance in cascade configurations


Typical Applications



  • ASE filtering in EDFA chains

  • Spontaneous emission suppression from DFB and tunable laser sources

  • Wavelength-selective component testing

  • WDM and DWDM system validation


Compatibility & Integration Standard FC/APC bulkheads interface with single-mode fiber systems. GPIB and RS-232 remote control enable integration into automated test benches and instrument control frameworks.

Specifications

ParameterValue
Voltage / Current Range100–240 V AC, 50–60 Hz
80 VA maximum | Wavelength Range1460–1575 nm

JDS Uniphase/JDSU TB9226-FA — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase/JDSU TB9226-FA. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase/JDSU TB9226-FA faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase/JDSU TB9226-FA price

This JDS Uniphase/JDSU TB9226-FA is listed at $4,830. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase/JDSU TB9226-FA calibration cost

NIST-traceable calibration for the JDS Uniphase/JDSU TB9226-FA is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents