Tektronix TR502 Tracking Generator Module, 100 kHz to 1.8 GHz
The Tektronix TR502 is a tracking generator module that operates from 100 kHz to 1.8 GHz. It is designed to work with Tektronix spectrum analyzers to provide a swept frequency response measurement capability. This module allows for scalar network analysis, enabling the characterization of filters, amplifiers, and other RF components.
- Model
- Tektronix TR502
- Calibration
- Available on request
- Price
- $3,479
- Status
- In stock
- RFQ ref
- TR502
This unit
The Tektronix TR502 Tracking Generator Module provides swept frequency response measurement capability when integrated with compatible Tektronix spectrum analyzers. Operating from 100 kHz to 1.8 GHz, it enables scalar network analysis for precise characterization of RF components including filters and amplifiers. The module plugs into TM500 or TM5000 series mainframes as a two-wide unit and delivers calibrated RF output with exceptional stability.
Technical Specifications
- Frequency Range: 100 kHz to 1.8 GHz
- Output Level: Maximum 0 dBm ±0.5 dB; adjustable 0 dBm to -59 dBm in 10 dB and 1 dB steps with additional 2 dB front panel attenuation
- Level Flatness: ±0.65 dB across 100 kHz to 1.8 GHz (TR502 standalone); ±1.65 dB from 100 kHz to 1.3 GHz and ±2 dB to 1.8 GHz (TR502/7L13 system)
- Output Impedance: 50 Ω nominal
- VSWR: 2:1 or less to 1.8 GHz
- Dynamic Range: ≥110 dB (TR502/7L13 system)
- Residual FM: 13 Hz or 1 Hz or less (TR502); 10 Hz or less (TR502/7L13 system)
- Spurious Output: Harmonic -20 dBc or better; non-harmonic -40 dBc or better
- Auxiliary RF Output: 0.1 V RMS minimum into 50 Ω load for frequency counter connection
- Operating Temperature: 0°C to +55°C
- Storage Temperature: -54°C to +75°C
- Weight: 8 lbs
Key Features
- Scalar network analysis for component characterization
- Stable, calibrated RF output across extended frequency range
- Dual RF outputs: main and auxiliary for counter integration
- Dot marker support with 7L13 spectrum analyzer via TRACK GEN LOGIC connector
- Flexible attenuation control: coarse (10 dB steps), fine (1 dB steps), and panel adjustment
Typical Applications Filter response measurement, amplifier characterization, RF component testing, impedance and reflection analysis.
Compatibility & Integration Spectrum Analyzers: Tektronix 7L12, 7L13, 7L14 Mainframes: TM500 and TM5000 series Frequency Counters: DC508 Option 7, DP501 prescaler with DC509, DC5009, DC510, or DC5010 via auxiliary RF output
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz to 1.8 GHz | Power Range (dBm): 0 dBm to -59 dBm (adjustable) |
| maximum 0 dBm ±0.5 dB | Voltage / Current Range | 0.1 V RMS (auxiliary RF output) |
Tektronix TR502 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Tektronix TR502. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Tektronix TR502 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Tektronix TR502 price
This Tektronix TR502 is listed at $3,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Tektronix TR502 calibration cost
NIST-traceable calibration for the Tektronix TR502 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →