Ametek / VTI Instruments / VXI Technology VM2710A 6.5 Digit Multimeter
Ametek / VTI Instruments / VXI Technology VXI Modules. Resolution: 4.5 to 6.5 digits, Current: 18% over-range.
- Model
- Ametek / VTI Instruments / VXI Technology VM2710A
- Calibration
- Available on request
- Price
- $1,800
- Status
- In stock
- RFQ ref
- VM2710A
This unit
The Ametek VTI Instruments VM2710A is a 6.5-digit multimeter engineered for automated test equipment and data acquisition systems. This VMIP™-family instrument mounts as a C-size VXIbus card, delivering over 2000 readings/second across the backplane - eliminating speed constraints imposed by onboard memory limits. Built-in limit checking and threshold-triggered VXIbus outputs reduce controller overhead.
Technical Specifications
Measurement Functions- DC Voltage (V dc)
- AC Voltage (V ac)
- DC Current (I dc)
- AC Current (I ac)
- 2-Wire Resistance
- 4-Wire Resistance Resolution & Speed
- Selectable resolution: 4.5 to 6.5 digits
- Reading rate: Greater than 2000 readings/second
- Programmable aperture times: 100 PLC, 10 PLC, 1 PLC, 0.1 PLC, 0.03 PLC
- On-board memory: Up to 256,000 readings with FIFO capability Measurement Ranges & Over-Range
- V dc and V ac: 20% over-range (except 300 V range)
- Current: 18% over-range
- Resistance: No over-range specified
- Accuracy varies by function, range, and aperture time (reference TCAL ±1 °C after 1-hour warm-up for sine-wave input ≥5% of range with Low-Frequency Filter ON) Triggering & Control
- Eight TTL backplane trigger inputs for measurement initiation
- Programmable trigger delays for external device synchronization
- Output trigger capability on dedicated backplane line upon measurement completion
- Software and hardware control modes
Key Features
- Two differential, isolated input channels for direct multiplexer connection or manual probing
- Programmable aperture times optimize resolution, accuracy, and noise rejection trade-offs
- On-board limit checking minimizes backplane traffic and controller processing
- Extensive triggering reduces system latency in synchronized multi-instrument setups
Typical Applications
- Production test and characterization of analog circuits
- Data acquisition requiring high-speed, high-resolution measurements
- Multi-channel measurement systems via VXI backplane integration
- Automated precision measurement under software control
Compatibility & Integration The VM2710A integrates into C-size VXI chassis as part of the VMIP™ ecosystem, supporting both software-controlled and hardware-triggered operation across the VXIbus backplane.
Ametek / VTI Instruments / VXI Technology VM2710A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ametek / VTI Instruments / VXI Technology VM2710A. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ametek / VTI Instruments / VXI Technology VM2710A faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Ametek / VTI Instruments / VXI Technology VM2710A price
This Ametek / VTI Instruments / VXI Technology VM2710A is listed at $1,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ametek / VTI Instruments / VXI Technology VM2710A calibration cost
NIST-traceable calibration for the Ametek / VTI Instruments / VXI Technology VM2710A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →