Ametek / VTI Instruments / VXI Technology VM7004-5 Programmable Resistor Module
The Ametek/VTI Instruments/VXI Technology VM7004-5 is a programmable resistor module designed for precision resistance simulation and calibration. It features a wide resistance range, high accuracy, and excellent stability. Ideal for automated testing and measurement applications, the VM7004-5 offers remote programmability via VXI interface, enabling seamless integration into existing test systems. This module is a reliable solution for demanding electronic testing environments.
- Model
- Ametek / VTI Instruments / VXI Technology VM7004-5
- Calibration
- Available on request
- Price
- $2,400
- Status
- In stock
- RFQ ref
- VM7004-5
This unit
The Ametek VM7004-5 is a four-channel programmable resistor module engineered for VXIbus test systems requiring precise resistance simulation, sensor emulation, and calibration functionality. This card delivers independent programmable resistance channels in a compact C-size form factor, with up to three modules stackable in a single slot for 12 total channels. Four-wire connections on each channel eliminate lead resistance effects, while a dedicated four-wire monitor bus enables in-system calibration and self-test routines.
Technical Specifications
Resistance Ranges (VM7004-5 Option)- 0 Ω to 163,830 Ω Alternate Options
- Option 6: 0 Ω to 1,638,300 Ω
- Option 7: 0 Ω to 16,383,000 Ω Standard Individual Channel Range
- 0 Ω to 16,383 Ω Parallel Configuration Ranges
- Two channels: 0 Ω to 8,192 Ω with 0.5 Ω step size
- Four channels: 0 Ω to 4,096 Ω with 0.25 Ω step size Series Configuration Ranges
- Two channels: 0 Ω to 32,768 Ω
- Four channels: 0 Ω to 65,536 Ω Accuracy
- ±0.02% of programmed value ± 0.5 Ω Electrical
- Maximum power dissipation: 0.5 W at 40°C
- Thermal offset: ≤ ±25 µV
Key Features
- Four independent programmable resistance channels per module
- Four-wire measurement connections for lead-resistance compensation
- Four-wire monitor bus for calibration and diagnostics
- Software-selectable operating modes: individual, potentiometer, parallel, and series configurations
- Message-based and register-based VXI control
- VXIplug&play driver compatibility
Typical Applications
- RTD and sensor emulation
- Process control simulation
- Automated test equipment (ATE) calibration
- System self-test and validation
Compatibility & Integration The VM7004-5 integrates into VXIbus C-size slots and supports standard VXI control protocols. Driver support via VXIplug&play simplifies deployment into existing test architectures.
Ametek / VTI Instruments / VXI Technology VM7004-5 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ametek / VTI Instruments / VXI Technology VM7004-5. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ametek / VTI Instruments / VXI Technology VM7004-5 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Ametek / VTI Instruments / VXI Technology VM7004-5 price
This Ametek / VTI Instruments / VXI Technology VM7004-5 is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ametek / VTI Instruments / VXI Technology VM7004-5 calibration cost
NIST-traceable calibration for the Ametek / VTI Instruments / VXI Technology VM7004-5 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →