Teledyne LeCroy WaveSurfer 4104HD 1 GHz, 12-bit High Definition Oscilloscope

Teledyne LeCroy Digital Oscilloscopes. Bandwidth: 1 GHz @ 50 Ω (ProBus input), Sensitivity: 1 mV/div to 10 V/div (1 MΩ), Accuracy: ±0.5% FS at 0 V offset.

Model
Teledyne LeCroy WaveSurfer 4104HD
Calibration
Available on request
Price
$22,479
Status
In stock
RFQ ref
WaveSurfer 4104HD
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Teledyne LeCroy WaveSurfer 4104HD is a 1 GHz, 12-bit high-definition digital oscilloscope built for signal analysis and troubleshooting across power electronics, automotive, and embedded design applications. The instrument delivers 12-bit vertical resolution via HD4096 technology - providing 4096 discrete levels and 16× greater resolution than conventional 8-bit oscilloscopes. This enables cleaner waveforms and superior signal fidelity for low-level measurements.


Four analog channels pair with optional 16 digital channels for mixed-signal capture. The 12.1-inch capacitive touch screen and MAUI with OneTouch interface streamline setup and operation.


Technical Specifications

Bandwidth & Sampling

  • Analog bandwidth: 1 GHz @ 50 Ω (ProBus input), 500 MHz @ 1 MΩ

  • Sampling rate: 5 GS/s (2 channels), 2.5 GS/s (4 channels), 10 GS/s random sampling

  • Rise time: 450 ps (10–90%, 50 Ω)

  • Acquisition memory: 12.5 Mpts (4 channels), 25 Mpts (2 channels) Vertical Resolution & Accuracy

  • 12-bit base resolution with Enhanced Resolution (ERES) up to 15 bits

  • Vertical sensitivity: 1 mV/div to 10 V/div (1 MΩ)

  • Vertical noise floor: 125 µVrms (1–5 mV/div) to 4.68 mVrms (1 V/div)

  • DC vertical gain accuracy: ±0.5% FS at 0 V offset

  • Channel isolation: 60 dB (DC–200 MHz), degrading to 40 dB at 1 GHz

  • Bandwidth limiting: 20 MHz, 200 MHz selectable Triggering

  • Maximum trigger frequency: 1 GHz (channels 1–4, external input, SMART Trigger)

  • Trigger modes: Normal, Auto, Single, Stop

  • Sources: Ch 1–4, EXT, EXT/5, AC Line

  • Coupling options: DC, AC, HFRej, LFRej

  • Pre-trigger delay: 0–100% of memory; post-trigger: 0–10,000 divisions

  • Hold-off: 10 ns to 20 s

  • Glitch and state-dependent trigger types supported Acquisition Modes


Real-time, Roll, Average, and Sequence modes with up to 1000 segmented memory blocks.

Key Features



  • 4 analog channels with optional 16 digital channels for MSO capability

  • HD4096 12-bit vertical resolution for signal detail and noise immunity

  • 1280 × 800 display with capacitive touch input

  • Intuitive MAUI OneTouch user interface


Typical Applications Power electronics characterization, automotive system diagnostics, embedded system signal validation, and general-purpose analog/mixed-signal troubleshooting.


Compatibility & Integration ProBus input connectors; supports standard oscilloscope probes and accessories.

Specifications

ParameterValue
Frequency RangeDC to 1 GHz | Voltage / Current Range: 1 mV/div to 10 V/div

Teledyne LeCroy WaveSurfer 4104HD — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Teledyne LeCroy WaveSurfer 4104HD. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Teledyne LeCroy WaveSurfer 4104HD price

This Teledyne LeCroy WaveSurfer 4104HD is listed at $22,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Teledyne LeCroy WaveSurfer 4104HD calibration cost

NIST-traceable calibration for the Teledyne LeCroy WaveSurfer 4104HD is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →