Acromag / Xembedded / Xycom XVME-212/1 Digital Input Module

Acromag / Xembedded / Xycom Digital Input Board. Frequency Range: DC to 3400 Hz, Voltage / Current Range: Logic 0: 0–1 VDC, Logic 1: 10–50 VDC, On-board 12 VDC isolated supply.

Model
Acromag / Xembedded / Xycom XVME-212/1
Calibration
Available on request
Price
$750
Status
In stock
RFQ ref
XVME-212/1
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Acromag/Xembedded/Xycom XVME-212/1 is a VMEbus-compliant digital input module delivering 32 optically isolated channels for industrial signal acquisition. Built on a double-height (233.7 mm × 160.0 mm) card, it eliminates host processor polling through programmable scanner circuitry that detects and reports state changes via VMEbus interrupt generation. Each channel features 300 VDC optical isolation and eight jumper-selectable debounce intervals to accommodate noisy field environments.


Technical Specifications



  • Channels: 32 digital inputs

  • Isolation: 300 VDC channel-to-channel and channel-to-VMEbus GND

  • Input Voltage Range: Logic 1: 10–50 VDC | Logic 0: 0–1 VDC

  • Reverse Bias Protection: 50 VDC

  • On-board Power Supply: Isolated 12 VDC (factory-connected for 12 V relay and switch monitoring; other 10–50 VDC inputs available with board modification)

  • Maximum Input Frequency: 3400 Hz

  • Minimum Detectable Pulse Width: Positive: 5–25 µsec typical / 100 µsec maximum | Negative: 150 µsec typical / 600 µsec maximum

  • Propagation Delay: Off-to-on: 5–25 µsec typical / 100 µsec maximum | On-to-off: 150 µsec typical / 600 µsec maximum

  • Operating Temperature: 0° to 65° C

  • Humidity: 20–80% RH, non-condensing

  • Shock: 50g peak acceleration, 11 msec duration

  • Vibration: 2.5g maximum acceleration, 0.030" peak-to-peak displacement

  • Altitude: Sea level to 10,000 ft.


Key Features



  • Programmable scanner circuitry for change-of-state detection

  • VMEbus interrupt capability (IEEE 1014 Rev. C.1 compliant)

  • Input debounce filtering with eight selectable intervals

  • A24/A16:D16/D08(EO) DTB slave operation


Typical Applications Pushbuttons, relay contacts, limit switches, proximity switches, photo-detector switches, pressure switches, alarm trip inputs.


Compatibility & Integration Fully compatible with VMEbus systems supporting A24/A16 addressing and D16/D08 data transfers.

Specifications

ParameterValue
Frequency RangeDC to 3400 Hz | Voltage / Current Range: Logic 0: 0–1 VDC, Logic 1: 10–50 VDC, On-board 12 VDC isolated supply

Acromag / Xembedded / Xycom XVME-212/1 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Acromag / Xembedded / Xycom XVME-212/1. Calibration covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Acromag / Xembedded / Xycom XVME-212/1 faults: ESD-damaged input protection, failed driver ICs, connector pin damage. Most failures involve ESD-damaged input protection circuitry, failed logic driver ICs, or mechanical connector pin damage. Board-level component replacement is standard practice.

Acromag / Xembedded / Xycom XVME-212/1 price

This Acromag / Xembedded / Xycom XVME-212/1 is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Acromag / Xembedded / Xycom XVME-212/1 calibration cost

NIST-traceable calibration for the Acromag / Xembedded / Xycom XVME-212/1 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers per-channel threshold accuracy, input leakage current, logic level high/low margins, and signal timing verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →