Fluke 113 True RMS Utility Multimeter with VCHECK
Fluke Laboratory Measurement Instruments.
- Model
- Fluke 113
- Calibration
- Available on request
- Price
- $179
- Status
- In stock
- RFQ ref
- 113
This unit
The Fluke 113 True RMS Utility Multimeter with VCHECK is a handheld instrument engineered for fundamental electrical testing and diagnostics. It delivers True-RMS AC voltage and current measurements with reliable accuracy on non-linear loads, and incorporates VCHECK™ LoZ low-impedance measurement capability for simultaneous voltage and continuity testing. This design eliminates ghost voltage errors and streamlines troubleshooting workflows for electricians, technicians, and utility workers.
Technical Specifications
The 6000-count display with backlight updates 4 times per second. Measurement ranges include AC voltage to 750 V (±2% rdg + 3 digits, 45 Hz to 1 kHz), DC voltage to 1000 V (±2% rdg + 3 digits, 0.001 V resolution), and resistance from 0.1 Ω to 40 MΩ across 600 Ω, 6 kΩ, and 60 kΩ ranges (0.9% + 1 to 2 accuracy). Continuity detection operates with beeper threshold 250 Ω, with 500 µs pulse sensitivity. Diode test covers 2 V range (±2.0% + 3). Capacitance measurement spans 0.01 nF to 100 µF across four ranges (1.9% to 5% + offset accuracy). Frequency measurement extends from 0.001 Hz to 10 MHz. Temperature measurement covers −20 to 750 °C. Duty cycle range is 0.1% to 99.9%. The instrument holds CAT III 600 V and CAT IV 300 V safety ratings.Key Features
- True-RMS capability ensures accurate AC measurements on non-linear loads
- VCHECK™ LoZ prevents false voltage readings and enables simultaneous testing
- Min/Max recording function captures signal fluctuations
- Auto and manual ranging modes
- Large backlit display for low-light environments
- Integral holster with probe storage
- 1-year calibration interval; accuracy specifications apply at 18 °C to 28 °C, 0% to 95% RH
Typical Applications Electrical system troubleshooting, voltage and continuity verification, component testing, load analysis on variable-frequency equipment.
Compatibility & Integration Two input jacks: COM (common terminal) and VΩCAP (voltage, resistance, capacitance). Dimensions: 167.1 mm × 85.1 mm × 46.0 mm. Weight: 404 g.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 0.001 Hz to 10 MHz | Voltage / Current Range: 1000 V, 750 V |
| DC | 600 V, AC: 600 V |
Fluke 113 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 113. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 113 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 113 price
This Fluke 113 is listed at $179. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 113 calibration cost
NIST-traceable calibration for the Fluke 113 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →