Fluke / Wavetek 1361 4.5 to 6.5 Digit Multimeter

The Fluke/Wavetek 1361 is a precision 4.5 to 6.5 digit multimeter designed for accurate voltage, current, and resistance measurements. It features a bright display, multiple measurement ranges, and solid construction for reliable performance in various testing environments. Ideal for electronics repair, calibration, and laboratory use.

Model
Fluke / Wavetek 1361
Calibration
Available on request
Price
$1,100
Status
In stock
RFQ ref
1361
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke/Wavetek 1361 is a VXI-based 6.5-digit digital multimeter engineered for high-precision automated measurements in test systems. This single-width C-size VXI module delivers programmable resolution from 4.5 to 6.5 digits with read rates up to 1000 readings per second, making it suitable for rapid characterization and production testing. Core measurement functions include DC voltage, AC voltage to 1000 Vrms, and resistance, with optional DC and AC current modules rated to 2 amperes. An internal data store buffers 1 to 1000 readings for continuous high-speed acquisition independent of system controller bandwidth.

Technical Specifications

Resolution: Programmable 4.5 to 6.5 digits

Read Rate: Up to 1000 readings/second

Measurement Functions: DCV, ACV (1000 Vrms), Ohms; optional DCI/ACI (2 A max)

Internal Data Store: 1–1000 readings

Common Mode Rejection Ratio: >146 dB

Normal Mode Rejection: >20 dB

Line Frequency Rejection: >54 dB at 50 Hz, 60 Hz, or 400 Hz (programmable)

VXI Compliance: Specification 1.4

Form Factor: Single-width C-size card, VXI backplane powered

Key Features

Floating input channel design isolates measurements from system ground

Dual trigger modes support internal system triggers and external TTL signals

Switchable active filters and digital filtering suppress AC line noise

SCPI-compatible command language integrates into automated test environments

VXI backplane connectivity provides power and trigger distribution

Typical Applications

Precision DC and AC voltage characterization in production test

Automated resistance and impedance measurement

High-speed transient capture with internal buffering

Multi-unit system integration via VXI backplane architecture

Compatibility & Integration The 1361 operates within VXIbus systems conforming to specification 1.4. SCPI command compatibility enables straightforward integration into existing test software and control frameworks. VXI backplane triggers enable deterministic measurement synchronization across multi-module systems.

Specifications

ParameterValue
Voltage / Current RangeACV up to 1000 Vrms

Fluke / Wavetek 1361 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke / Wavetek 1361. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke / Wavetek 1361 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Fluke / Wavetek 1361 price

This Fluke / Wavetek 1361 is listed at $1,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke / Wavetek 1361 calibration cost

NIST-traceable calibration for the Fluke / Wavetek 1361 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents