Fluke 179 True RMS Digital Multimeter with built-in thermometer
The Fluke 179 True RMS Digital Multimeter is a versatile tool for electrical troubleshooting. It measures AC/DC voltage and current, resistance, capacitance, frequency, and temperature. Its True RMS accuracy ensures precise readings on non-linear signals. Includes a built-in thermometer for temperature measurements.
- Model
- Fluke 179
- Calibration
- Available on request
- Price
- $430
- Status
- In stock
- RFQ ref
- 179
This unit
The Fluke 179 True RMS Digital Multimeter combines electrical measurement, temperature sensing, and diagnostic capability in a single instrument for industrial and utility troubleshooting. It delivers True RMS AC/DC voltage and current measurements alongside resistance, capacitance, frequency, continuity, and diode testing. The integrated thermometer eliminates the need for a separate probe, measuring temperature from −40 °C to +400 °C with ±(1.0% + 10) accuracy.
Technical Specifications Voltage & Current Measurement
DC Voltage: 0.1 mV to 1000 V, 0.1 mV resolution, ±0.09% basic accuracy
AC Voltage (True RMS): 0.1 mV to 1000 V, 1 kHz frequency response, ±1.0% basic accuracy
DC Current: 0.01 mA to 10.00 A (20.00 A overrange for 30 s), 0.01 mA resolution, ±1% basic accuracy
AC Current (True RMS): 0.01 mA to 10.00 A (20.00 A overrange for 30 s), ±1.5% basic accuracy (500 Hz to 1 kHz) Passive Measurements
Resistance: 0.1 Ω to 50.00 MΩ, 0.1 Ω resolution
Capacitance: 1 nF to 9999 µF, 0.01 nF resolution, 1.2% accuracy (≤1000 µF)
Frequency: 2 Hz to 50 kHz (DMM functions), 2 Hz to 99.99 kHz (AC/DC voltage), 2 Hz to 30 kHz (current), 0.01 Hz resolution
Diode Test: 2.400 V range, 0.001 V resolution
Continuity: Beeper guaranteed <25 Ω; detects opens/shorts ≥250 µs Temperature
Range: −40 °C to +400 °C, 0.1 °C resolution, ±(1.0% + 10) accuracy
Key Features
6000-count digital display, 4 updates/second; 33-segment analog bargraph at 40 updates/second
Manual and automatic ranging modes
Display HOLD and Auto HOLD with stable-reading detection
MIN MAX AVG recording function
Backlit display with 2-minute auto-off; user-disableable
CAT III 1000 V / CAT IV 600 V safety rating
Front-panel closed-case calibration
Typical Applications Electrical troubleshooting, HVAC system diagnostics, industrial maintenance, field service, and temperature verification in control systems.
Compatibility & Integration Dimensions: 7.28 in H × 3.54 in W. Suitable for deployment in CAT III and CAT IV environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 Hz to 99.99 kHz | Voltage / Current Range: 0.01 mA to 10.00 A (20.00 A overrange), 0.1 mV to 1000 V |
Fluke 179 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 179. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 179 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 179 price
This Fluke 179 is listed at $430. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 179 calibration cost
NIST-traceable calibration for the Fluke 179 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →