Keithley 193A System Digital Multimeter

Keithley Laboratory Measurement Instruments. Voltage: 100 nV to 1000 V, Current: 1 nA to 2 A (with 1931 Current option), Bandwidth: Typically 500 kHz (3 dB).

Model
Keithley 193A
Calibration
Available on request
Price
$570
Status
In stock
RFQ ref
193A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 193A System Digital Multimeter is a instrument for precision measurement and automated testing. It delivers 6½-digit resolution across DC and AC voltage, current, resistance, and temperature measurement functions. The 193A integrates IEEE-488 programmability for direct integration into automated test systems, internal data storage for up to 500 readings, and configurable digital filtering to optimize measurement stability across demanding R&D, calibration, and manufacturing workflows.

Technical Specifications Measurement Ranges

DC Voltage: 100 nV to 1000 V

AC Voltage (TRMS): 1 µV to 700 V (with 1930 True RMS ACV option)

DC Current: 1 nA to 2 A (with 1931 Current option)

AC Current (TRMS): 1 nA to 2 A (with 1930 and 1931 options installed)

Resistance (4-Wire): 200 Ω to 200 MΩ

Temperature: RTD −100°C to 630°C; Thermocouple types J, K, T, E, R, S, B via IEEE-488

dB measurements available

TRMS AC + DC measurements supported Performance

Display: 14-character alphanumeric LED, ±2,200,000 counts

A/D Converter: Greater than ±1,999,999 count range

Measurement Rate: Up to 1000 readings per second (internal memory, filter and multiplex off)

AC Voltage Bandwidth: Typically 500 kHz (3 dB)

Key Features

Digital Filter: Weighted average, settable 1 to 99 readings via front panel or bus

Zero Function: Offset cancellation and baseline establishment; programmable locally or over IEEE-488

Internal Buffer: Stores up to 500 readings

Digital Calibration: Accessible from front panel or IEEE-488 bus

User-Programmable Defaults: Configure any measurement setup as power-up state

Translator Software: Define custom command words for IEEE-488 operation

Compatibility & Integration

IEEE-488 Interface: Full programmability and remote control

Power: 105–125 V or 210–250 V, 50–60 Hz, 40 VA

Optional voltage ranges: 90–110 V or 180–220 V

Available Options: 1930 True RMS ACV, 1931 Current module, CAL calibration

Specifications

ParameterValue
Voltage / Current Range50–60 Hz, DC Voltage: 100 nV to 1000 V
AC Voltage1 µV to 700 V
DC Current1 nA to 2 A
AC Current1 nA to 2 A
Power105–125 V or 210–250 V

Keithley 193A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 193A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 193A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 193A price

This Keithley 193A is listed at $570. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 193A calibration cost

NIST-traceable calibration for the Keithley 193A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents