Keithley 195A Digital Multimeter with 1950 AC Option
Keithley Laboratory Measurement Instruments. Voltage: 20mV to 1000V full scale, Bandwidth: 3 dB at 250 kHz typical.
- Model
- Keithley 195A/1950
- Calibration
- Available on request
- Price
- $280
- Status
- In stock
- RFQ ref
- 195A/1950
This unit
The Keithley 195A is a 5.5-digit digital multimeter delivering high-resolution electrical measurements across DC voltage, resistance, and - with the 1950 AC Option
AC voltage and DC current. Manual or fast autoranging (150ms per range change on DCV) enables rapid measurement cycles, while a standard GPIB interface integrates directly into automated test systems. The instrument achieves 200,000-count resolution on a LED display and stabilizes to rated accuracy within 1 hour of warmup.
Technical Specifications
Measurement Ranges & Accuracy- DC Voltage: 20mV to 1000V full scale; ±(0.025% reading + 6–8 counts) depending on range
- AC Voltage (1950 Option): 200mV to 700V; ±(0.3% reading + 200 counts) at 45Hz–10kHz, True RMS response
- Resistance: 20Ω to 20MΩ across seven ranges; ±(0.022–0.050% reading + 5–25 counts); automatic 2- or 4-terminal configuration
- DC Current (1950 Option): 20µA to 2A; resolution from 100pA full scale
- AC Current (1950 Option): 1nA to 2A, True RMS Input Characteristics
- DC Voltage Input Impedance: >1 GΩ (10 MΩ on 20V and above ranges)
- AC Voltage Input Impedance: 2 MΩ shunted by <75 pF; bandwidth -3 dB at 250 kHz typical
- Maximum Input: 1000V peak (DC and AC); AC also limited to 107 V·Hz
- Crest Factor: Up to 3:1 allowable for AC measurements Environmental & Physical
- Operating: 0°C to 50°C, 0–80% RH (to 35°C)
- Storage: -25°C to 65°C
- Power: 105–125V or 210–250V selectable, 50–400 Hz, 24 VA maximum
- Dimensions: 127 mm H × 216 mm W × 359 mm D
- Weight: 3.2 kg
Key Features
- 5.5-digit LED display (200,000 counts)
- Fast autoranging with 150 ms per-range settling on DCV
- True RMS AC measurements with AC coupling
- Automatic 2- and 4-terminal resistance measurement
- Temperature coefficient: <±(0.1 × accuracy)/°C across 0–18°C and 28–50°C
- Reading rate: 3 readings/second (1 reading/second on 20 MΩ range)
Typical Applications
- Electronics assembly and component validation
- Laboratory bench testing and general electrical measurement
- Automated test system integration via GPIB
Compatibility & Integration Standard GPIB interface supports integration into ATE platforms. 90–110 V and 180–220 V power supply versions available on request.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 45 Hz to 250 kHz | Voltage / Current Range: DC: 100 nV to 1000 V |
| AC Voltage | 1 µV to 700 V |
| AC Current | 1 nA to 2 A |
| DC Current | 100 pA to 2 A |
| Resistance | 100 µΩ to 20 MΩ |
Keithley 195A/1950 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley 195A/1950. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley 195A/1950 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keithley 195A/1950 price
This Keithley 195A/1950 is listed at $280. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley 195A/1950 calibration cost
NIST-traceable calibration for the Keithley 195A/1950 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →