Keithley 2100/230-240 – 6½-Digit USB Multimeter

Keithley Laboratory Measurement Instruments. Resolution: ** 6½ digits.

Model
Keithley 2100/230-240
Calibration
Available on request
Price
$625
Status
In stock
RFQ ref
2100/230-240
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2100/230-240 is a 6½-digit USB digital multimeter engineered for precision measurement across benchtop and system applications. It delivers 0.0038% basic DC voltage accuracy on the 10V range and 0.013% resistance accuracy on the 10kΩ range, supporting measurements in DC/AC voltage, DC/AC current, resistance, frequency, period, temperature, diode testing, and continuity. The instrument achieves 50 triggered readings per second at full 6½-digit resolution via USB, or exceeds 2000 readings per second at 4½-digit resolution when using fast measurement mode with internal 2000-reading buffer storage.

Technical Specifications

Resolution: 6½ digits

DC Voltage Accuracy (1-year, 10V range): 0.0038%

Resistance Accuracy (1-year, 10kΩ range): 0.013%

Measurement Rate (USB): 50 triggered readings/s at 6½ digits

Measurement Rate (Fast Mode): >2000 readings/s at 4½ digits into 2000-reading buffer

DC Voltage Ranges: 0.1V, 1V, 10V, 100V, 1000V

AC Voltage Ranges: 0.1V, 1V, 10V, 100V, 750V (True RMS)

DC Current Ranges: 10mA, 100mA, 1A, 3A

AC Current Ranges: 1A, 3A (True RMS)

Resistance Ranges: 100Ω to 100MΩ; maximum 0.1GΩ measurement capability

Frequency Measurement: 3 Hz to 300 kHz

Temperature Measurement: -100°C to +630°C

Input Protection: 1000V on all 2-wire resistance ranges

Math Functions: RATIO, %, Min/Max, NULL, Limits, mX+b, dB, dBm

Operating Temperature: 5°C to 40°C

Key Features

5x7 dot matrix VFD with three-color annunciators

USB 2.0 TMC-compliant interface for SCPI test program control

Selectable front/rear inputs for bench or rack deployment

Rugged construction with removable rubber bumpers and integrated carrying handle

Included PC software utilities for graphing and data export to Microsoft Office, Word, and Excel

Typical Applications This multimeter serves R&D laboratories, system integrators, and field technicians requiring high-resolution DC/AC measurements, component characterization, and automated test sequences via USB control.

Compatibility & Integration USB 2.0 TMC interface supports SCPI programming. Software packages provide integration with Microsoft Office suite and Excel for real-time data visualization and analysis.

Specifications

ParameterValue
Frequency Range3 Hz to 300 kHz | Voltage / Current Range: DC Voltage: 0.1V–1000V
AC Voltage0.1V–750V
DC Current10mA–3A
AC Current1A–3A

Keithley 2100/230-240 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2100/230-240. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 2100/230-240 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 2100/230-240 price

This Keithley 2100/230-240 is listed at $625. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2100/230-240 calibration cost

NIST-traceable calibration for the Keithley 2100/230-240 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →