Fluke 8024B Digital Multimeter

The Fluke 8024B is a solid digital multimeter designed for electronics troubleshooting and general-purpose measurements. It features a clear digital display, measures voltage, current, resistance, and includes diode test functionality. Ideal for field service, benchtop repair, and hobbyist use.

Model
Fluke 8024B
Calibration
Available on request
Price
$79
Status
In stock
RFQ ref
8024B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 8024B is a portable digital multimeter engineered for electronics troubleshooting and field measurements across DC/AC voltage, current, resistance, and specialized signal analysis. Its dual-slope integration architecture delivers noise-free measurements with a 3½-digit LCD display (1,999 count maximum) featuring autozero and autopolarity. The instrument captures transient signals via peak-hold, detects logic levels up to 250 V AC/DC RMS, and tests continuity with visual and audible indication. Diode testing and temperature measurement (K-type thermocouple, not included) extend diagnostic capability. A single 9 V battery powers the meter for approximately 100 hours with alkaline chemistry, with low-battery indication displayed as "BT" at ≈20% capacity. Overload protection on all ranges and glass fuse input protection ensure safe operation. The compact design - 18.0 cm × 8.6 cm × 4.5 cm, 0.48 kg - fits standard tool kits. Safety-featured test leads with finger guards and shrouded connectors meet CAT II measurement category requirements.

Technical Specifications

Display: 3½-digit LCD, 1,999 count maximum; autozero and autopolarity

DC Voltage: 200 mV to 1,000 V

AC Voltage: 200 mV to 750 V (average sensing, RMS-indicating)

DC Current: 2 mA to 2,000 mA

AC Current: 2 mA to 2,000 mA

Resistance: 200 Ω to 20 MΩ

Conductance: Up to 10,000 MΩ

Peak-Hold: Transient AC/DC signal capture

Level Detector: Logic levels and active signals to 250 V AC/DC RMS

Common Mode Voltage: Maximum 500 V DC or RMS

Measurement Category: CAT II

Input Protection: Glass fuse and clamping circuit

Calibration Stability: 2-year cycle

Key Features

Dual-slope integration for noise-free measurements

Diode test and continuity testing with audible feedback

Temperature measurement capability (thermocouple not included)

Effective overload protection across all ranges

High-contrast LCD readable at distance

Low-battery indicator

Power & Operating Conditions

Power Source: Single 9 V battery (NEDA 1604)

Battery Life: Alkaline 100 hours typical; zinc carbon 50 hours typical

Operating Temperature: 0 °C to 50 °C

Storage Temperature: -35 °C to +60 °C

Line Operation: Compatible with Model A81 Battery Eliminator

Typical Applications Electronics service and repair, HVAC troubleshooting, automotive diagnostics, and preventive maintenance where transient signal capture and logic-level detection are required.

Specifications

ParameterValue
Voltage / Current Range000 mA, 000 V, AC Current: 2 mA to 2, AC Voltage: 200 mV to 750 V, DC Current: 2 mA to 2, DC Voltage: 200 mV to 1, Resistance: 200 Ω to 20 MΩ

Fluke 8024B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 8024B. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 8024B faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 8024B price

This Fluke 8024B is listed at $79. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 8024B calibration cost

NIST-traceable calibration for the Fluke 8024B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents