Astronics / EADS / Racal 2461-Cd Universal Counter Timer VXI Card

The Astronics/EADS/Racal 2461-Cd is a Universal Counter Timer VXI Card designed for a wide range of timing and frequency measurement applications. This VXI card offers high-resolution timing, frequency, period, pulse width, and phase measurements. Ideal for automated test equipment (ATE) systems, calibration labs, and research and development environments, it provides precise and reliable performance.

Model
Astronics / EADS / Racal 2461-Cd
Calibration
Available on request
Price
$1,800
Status
In stock
RFQ ref
2461-Cd
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Astronics/EADS/Racal 2461-Cd is a C-size VXI universal counter timer card delivering precision frequency, timing, and voltage measurements for automated test equipment, calibration labs, and R&D environments. This module functions as a direct replacement for legacy Racal 2461 variants and Keysight E1420A/B models. The -Cd configuration omits an internal oscillator, requiring external timebase sourcing.

Technical Specifications Measurement Performance

Frequency measurement to 200 MHz with 9–10 digit/second resolution

Time interval: 1 ns single-shot resolution; 100 ps average mode resolution

Pulse characterization: automatic rise time, fall time, and pulse width measurement

Phase measurement: automatic phase detection supported

DVM voltage measurement: ±5.1 V standard range; ±42–51 V with ×10 attenuation; ±200 V with ×40 attenuation (2461A)

Trigger resolution: 2.5 mV

Key Features

Automatic measurement functions: frequency, period, time interval, rise/fall time, pulse width, duty cycle, frequency ratio, totalize, phase, and DVM

Nine-mode arming capability with selectable sources from external inputs or VXI TTL trigger lines

Programmable measurement timeout for systems with intermittent or absent input signals

Internal storage capacity: 14,000 readings

Per-channel 50 kHz low-pass filters with selectable hysteresis for noise mitigation

Adjustable sensitivity for low-level and noisy signal optimization

Time Error Correction (TEC) and recipromatic techniques minimize measurement time without performance loss

Typical Applications Frequency and timing validation in production test; component characterization in R&D; precision voltage and phase measurements in calibration workflows; automated multifunction parameter acquisition in instrument racks.

Compatibility & Integration VXIbus C-size module. Functional replacement for Racal 2461 (Cd, Ce, S-2276B, S-2391B) and Keysight E1420A/B. Related -Ce variant includes TCXO; -Cf includes oven-controlled crystal oscillator.

Specifications

ParameterValue
Frequency RangeDC to 200 MHz | Voltage / Current Range: ±5.1 V standard

Astronics / EADS / Racal 2461-Cd — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Astronics / EADS / Racal 2461-Cd. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Astronics / EADS / Racal 2461-Cd faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.

Astronics / EADS / Racal 2461-Cd price

This Astronics / EADS / Racal 2461-Cd is listed at $1,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Astronics / EADS / Racal 2461-Cd calibration cost

NIST-traceable calibration for the Astronics / EADS / Racal 2461-Cd is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents