Keithley 2502 Fiber Alignment Photodiode Meter
Keithley Optical Power Meters. Current: 50 fA max @ 23°C, Voltage: 200 VDC, Accuracy: Key Features.
- Model
- Keithley 2502
- Calibration
- Available on request
- Price
- $2,880
- Status
- In stock
- RFQ ref
- 2502
This unit
The Keithley 2502 Fiber Alignment Photodiode Meter is a dual-channel instrument engineered for precision optical power measurements and fiber-to-photodiode alignment optimization. It minimizes insertion loss and maximizes signal strength in fiber optic systems through accurate current and voltage characterization. The 2502 serves research, development, and manufacturing environments requiring critical fiber alignment for product performance and quality control.
Technical Specifications
Measurement Ranges & Resolution- Current measurement: 1 fA to 20 mA, 1 fA resolution
- Voltage bias source: ±10 V or ±100 V selectable
- Dark current measurement: 2 nA range optimized at 1 fA resolution with REL function for offset subtraction
- Maximum voltage source/measure: 100 V
- Analog output: 0–10 V for optical power feedback Electrical Performance
- Measurement speed: 900 readings per second per channel at 4½-digit resolution
- Input bias current: 50 fA max @ 23°C
- Input voltage burden: 4.0 mV max
- Voltage source slew rate: 3.0 ms/V typical
- Common mode voltage: 200 VDC
- Common mode isolation: 10⁹ Ω typical in parallel with 150 nF
- Source capacitance: 10.0 nF typical Data & Control
- Buffer memory: 3000-point per channel (6000 total) with timestamp logging
- Digital I/O: 1 trigger input, 4 TTL/relay drive outputs (33 V @ 500 mA, diode clamped)
- Serial interfaces: IEEE-488 and RS-232
- Trigger Link hardware handshaking Physical & Environmental
- Dimensions: 89 mm H × 213 mm W × 370 mm D
- Weight: 6.8 kg
- Power supply: 100/120/220/240 V ±10%, selectable; 50/60 Hz
- Power dissipation: 60 VA
- Vibration: MIL-T-28800F
- Warm-up time: 1 hour to rated accuracy
Key Features
- Dual-channel simultaneous measurement with independent bias control
- Selectable ±10 V (large-area photodiodes) and ±100 V (avalanche photodiodes) bias ranges
- LIV testing capability for laser diode modules integrating alignment and characterization
- Optical power measurement when paired with Model 2500INT Integrating Sphere
- High-speed data acquisition up to 900 readings/second per channel
Typical Applications
- Fiber-to-photodiode alignment and optimization
- Photodiode dark current and responsivity characterization
- Laser diode module LIV testing
- Optical power measurement in fiber optic component development
- Quality control and performance validation in manufacturing
Compatibility & Integration The 2502 interfaces via IEEE-488 and RS-232 for system integration. TTL/relay outputs and trigger inputs enable synchronization with external test equipment and automation systems. Integration with the Model 2500INT Integrating Sphere extends measurement capability to direct optical power assessment.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | ±10 V or ±100 V selectable bias |
Keithley 2502 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley 2502. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley 2502 faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.
Keithley 2502 price
This Keithley 2502 is listed at $2,880. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley 2502 calibration cost
NIST-traceable calibration for the Keithley 2502 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →