HP / Agilent 3324A Synthesized Function/Sweep Generator

The HP/Agilent 3324A is a synthesized function/sweep generator capable of producing a wide range of waveforms and sweep functions. It offers precise frequency control and versatile modulation capabilities for various testing and measurement applications.

Model
HP / Agilent 3324A
Calibration
Available on request
Price
$238
Status
In stock
RFQ ref
3324A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3324A is a synthesized function and sweep generator delivering precise waveform synthesis across audio through RF bands. It generates sine, square, triangle, ramp, DC, and TTL clock signals with frequency resolution to 1 mHz and accuracy of ±5 ppm. The instrument excels in broadband sweep applications, supporting linear, logarithmic, and multi-interval modes with up to 100 intervals in user-defined sequences. Phase-continuous sweeping across the full frequency range ensures clean transitions for characterization and testing tasks. Sine waveforms reach 21 MHz with exceptional spectral purity at -50 dBc phase noise and -55 dBc spurious content. Amplitude control spans 1 mV to 10 V peak-to-peak into 50Ω loads, with optional high-voltage output extending to 40 V peak-to-peak into 500Ω loads to 1 MHz. The 50Ω output impedance and floating capability to 40 V support flexible test configurations. An optional high-stability frequency reference achieves 0.05 ppm/week drift after stabilization, meeting precision calibration and long-duration measurement requirements.

Technical Specifications

Frequency Range (Sine): 1 mHz to 21 MHz

Frequency Range (Square): 1 mHz to 11 MHz

Frequency Range (Triangle/Ramp): 1 mHz to 11 kHz

Frequency Resolution: 1 mHz (9-digit display)

Frequency Accuracy: ±5 ppm at 20–30°C (at calibration)

Frequency Stability: ±5 ppm/year (standard); 0.05 ppm/week (Option 001, after 72 h)

Amplitude Range: 1 mV to 10 V peak-to-peak into 50Ω; up to 40 V into 500Ω (Option 002, to 1 MHz)

Amplitude Accuracy: ±2% at 2 kHz

Amplitude Flatness: ±10% relative to programmed value

DC Offset Range: ±4× instrument standard range

Output Impedance: 50Ω ±10% (DC–10 kHz); <3Ω DC; <10Ω at 1 MHz

Output Floating: ±40 V (42 V peak AC+DC maximum)

Sine Spectral Purity: -50 dBc phase noise; -55 dBc spurious

Triangle/Ramp Linearity: 0.05% of full peak-to-peak

Ramp Retrace Time: 3 ps (90%–10%, 50Ω/500 pF load)

Square Wave Overshoot: 10% peak-to-peak (50Ω/500 pF load)

Sweep Modes: Linear (10 ms–100 s); Logarithmic (100 ms–1000 s); Multi-Interval (up to 100 intervals)

Minimum Sweep Width: 1 decade

Phase Offset: ±719.9° adjustable

Key Features

Nine-digit frequency display for precise readout and verification

Phase-continuous sweeping eliminates glitches during frequency transitions

Multi-interval sweep sequences enable complex, application-specific test profiles

TTL clock output for digital synchronization

GPIB interface with floating capability for isolated test setups

Typical Applications

Component characterization and filter response measurement

Frequency response testing of analog and mixed-signal circuits

Production testing and automated calibration workflows

Educational laboratory demonstrations and circuit validation

Compatibility & Integration GPIB programming interface. Floating outputs support isolated measurement environments.

Specifications

ParameterValue
Frequency Range1 mHz to 21 MHz (sine)
1 mHz to 11 kHz (triangle/ramp) | Voltage / Current Range1 mV to 10 V peak-to-peak (into 50Ω)

HP / Agilent 3324A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3324A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3324A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

HP / Agilent 3324A price

This HP / Agilent 3324A is listed at $237.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3324A calibration cost

NIST-traceable calibration for the HP / Agilent 3324A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →