HP / Agilent 3324A Synthesized Function/Sweep Generator
The HP/Agilent 3324A is a synthesized function/sweep generator capable of producing a wide range of waveforms and sweep functions. It offers precise frequency control and versatile modulation capabilities for various testing and measurement applications.
- Model
- HP / Agilent 3324A
- Calibration
- Available on request
- Price
- $238
- Status
- In stock
- RFQ ref
- 3324A
This unit
The HP/Agilent 3324A is a synthesized function and sweep generator delivering precise waveform synthesis across audio through RF bands. It generates sine, square, triangle, ramp, DC, and TTL clock signals with frequency resolution to 1 mHz and accuracy of ±5 ppm. The instrument excels in broadband sweep applications, supporting linear, logarithmic, and multi-interval modes with up to 100 intervals in user-defined sequences. Phase-continuous sweeping across the full frequency range ensures clean transitions for characterization and testing tasks. Sine waveforms reach 21 MHz with exceptional spectral purity at -50 dBc phase noise and -55 dBc spurious content. Amplitude control spans 1 mV to 10 V peak-to-peak into 50Ω loads, with optional high-voltage output extending to 40 V peak-to-peak into 500Ω loads to 1 MHz. The 50Ω output impedance and floating capability to 40 V support flexible test configurations. An optional high-stability frequency reference achieves 0.05 ppm/week drift after stabilization, meeting precision calibration and long-duration measurement requirements.
Technical Specifications
Frequency Range (Sine): 1 mHz to 21 MHz
Frequency Range (Square): 1 mHz to 11 MHz
Frequency Range (Triangle/Ramp): 1 mHz to 11 kHz
Frequency Resolution: 1 mHz (9-digit display)
Frequency Accuracy: ±5 ppm at 20–30°C (at calibration)
Frequency Stability: ±5 ppm/year (standard); 0.05 ppm/week (Option 001, after 72 h)
Amplitude Range: 1 mV to 10 V peak-to-peak into 50Ω; up to 40 V into 500Ω (Option 002, to 1 MHz)
Amplitude Accuracy: ±2% at 2 kHz
Amplitude Flatness: ±10% relative to programmed value
DC Offset Range: ±4× instrument standard range
Output Impedance: 50Ω ±10% (DC–10 kHz); <3Ω DC; <10Ω at 1 MHz
Output Floating: ±40 V (42 V peak AC+DC maximum)
Sine Spectral Purity: -50 dBc phase noise; -55 dBc spurious
Triangle/Ramp Linearity: 0.05% of full peak-to-peak
Ramp Retrace Time: 3 ps (90%–10%, 50Ω/500 pF load)
Square Wave Overshoot: 10% peak-to-peak (50Ω/500 pF load)
Sweep Modes: Linear (10 ms–100 s); Logarithmic (100 ms–1000 s); Multi-Interval (up to 100 intervals)
Minimum Sweep Width: 1 decade
Phase Offset: ±719.9° adjustable
Key Features
Nine-digit frequency display for precise readout and verification
Phase-continuous sweeping eliminates glitches during frequency transitions
Multi-interval sweep sequences enable complex, application-specific test profiles
TTL clock output for digital synchronization
GPIB interface with floating capability for isolated test setups
Typical Applications
Component characterization and filter response measurement
Frequency response testing of analog and mixed-signal circuits
Production testing and automated calibration workflows
Educational laboratory demonstrations and circuit validation
Compatibility & Integration GPIB programming interface. Floating outputs support isolated measurement environments.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1 mHz to 21 MHz (sine) |
| 1 mHz to 11 kHz (triangle/ramp) | Voltage / Current Range | 1 mV to 10 V peak-to-peak (into 50Ω) |
HP / Agilent 3324A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3324A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 3324A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.
HP / Agilent 3324A price
This HP / Agilent 3324A is listed at $237.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 3324A calibration cost
NIST-traceable calibration for the HP / Agilent 3324A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →