HP / Agilent 3314A Programmable Function Generator

The HP/Agilent 3314A is a programmable function generator capable of producing a wide range of waveforms, including sine, square, triangle, and ramp functions. It offers precise control over frequency, amplitude, and offset, making it suitable for various testing and measurement applications. The 3314A features programmable parameters and modulation capabilities.

Model
HP / Agilent 3314A
Calibration
Available on request
Price
$238
Status
In stock
RFQ ref
3314A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3314A is a programmable function generator delivering sine, square, triangle, ramp, and pulse waveforms from 0.001 Hz to 19.99 MHz, with ramp and pulse capabilities to 2 MHz. It generates arbitrary waveforms from user-defined vectors stored in non-volatile memory and supports amplitude outputs from 0.01 mVp-p to 10 Vp-p into 50 Ω, expandable to 30 Vp-p into loads exceeding 500 Ω with Option 001. Independent ±5 V DC offset can be applied to any AC signal using post-attenuator summing. Variable symmetry control (5% to 95%) enables pulse generation with rise/fall times as low as 9 ns for digital circuit testing and positive or negative ramps for amplifier characterization. The instrument integrates AM and FM/VCO modulation at 100 kHz bandwidth, linear and logarithmic sweeping, and multiple trigger modes including N-cycle burst (1 to 1999 cycles), gate mode, and 1/2-cycle generation. Phase lock synchronization (XN and ÷N) and variable start/stop phase control support specialized waveform synthesis. Frequency accuracy reaches 0.01% on upper ranges with sine distortion below −55 dBc to 50 kHz. Internal triggering spans 0.5 mHz to 500 kHz; external triggering is supported for burst and gate modes with trigger output for device synchronization. Full HP-IB programmability integrates the 3314A into automated test equipment and complex measurement systems.

Technical Specifications

Frequency Range: 0.001 Hz to 19.99 MHz (sine, square, triangle); ramp and pulse to 2 MHz

Amplitude: 0.01 mVp-p to 10 Vp-p into 50 Ω; optional 30 Vp-p into >500 Ω with Option 001

DC Offset: Independent ±5 V into 50 Ω

Frequency Accuracy: 0.01% on upper ranges

Sine Distortion: <−55 dBc to 50 kHz

Symmetry Control: 5% to 95% (ramps and pulses)

Pulse Rise/Fall Time: As low as 9 ns

Arbitrary Waveforms: Up to 150 vectors with non-volatile storage

Modulation Bandwidth: 100 kHz (AM and FM/VCO)

Burst Mode: 1 to 1999 cycles

Internal Trigger Range: 0.5 mHz to 500 kHz

Key Features

Variable symmetry for narrow pulse and ramp generation

N-cycle burst and gate modes for signal sequencing

Phase lock and variable start/stop phase for synchronized outputs

Linear and logarithmic sweep with manual control

Arbitrary waveform generation with persistent memory

AM and FM/VCO modulation usable separately or simultaneously

External and internal triggering with synchronization output

Typical Applications

Digital circuit testing with sub-nanosecond pulse generation

Filter and amplifier network characterization via frequency sweeps

Sonar and transducer signal simulation

Process control and feedback loop testing

Automated test environments requiring synchronized multi-instrument operation

Compatibility & Integration

HP-IB programmable interface for all front panel controls

Suitable for automated test systems and benchtop integration

Trigger output for external device synchronization

Specifications

ParameterValue
Frequency Range0.001 Hz to 19.99 MHz (sine, pulse), square, triangle)
0.001 Hz to 2 MHz (ramp | Voltage / Current Range0.01 mVp-p to 10 Vp-p into 50 Ω

HP / Agilent 3314A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3314A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3314A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

HP / Agilent 3314A price

This HP / Agilent 3314A is listed at $237.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3314A calibration cost

NIST-traceable calibration for the HP / Agilent 3314A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →