HP / Agilent 4275A LCR METER

The HP/Agilent 4275A is a precision LCR meter designed for accurate and reliable impedance measurements. It operates at various frequencies to characterize components and materials. Ideal for electronics manufacturing, quality control, and research applications.

Model
HP / Agilent 4275A
Calibration
Available on request
Price
$1,260
Status
In stock
RFQ ref
4275A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 4275A is a precision microprocessor-based LCR meter for accurate impedance characterization across 10 kHz to 10 MHz. It measures inductance, capacitance, resistance, impedance, dissipation factor, quality factor, ESR, conductance, susceptance, reactance, and phase angle with 0.1% basic accuracy and 5½ digit resolution. The instrument supports auto, series, and parallel measurement modes with continuously variable test signal levels from 1 mVrms to 1 Vrms.


Typical measurement time is 140–180 ms above 1 kHz. A four-terminal pair configuration with guard terminal minimizes lead and fixture effects. Automatic zero-offset capability compensates for residual impedance.


Deviation measurement displays absolute or percentage difference from stored reference values.


Technical Specifications



  • Measurement Parameters: L, C, R, |Z|, D, Q, ESR, G, X, B, and phase angle

  • Frequency Range: 10 kHz to 10 MHz with 10 or 12 selectable spot frequencies in 1-2-4-10 sequence. Optional frequencies: 455 kHz and 10.7 MHz

  • Test Signal Level: 1 mVrms to 1 Vrms continuously variable across 3 ranges

  • Basic Accuracy: 0.1%

  • Resolution: 5½ digits for primary parameters; 0.00001 for dissipation factor (D)

  • Measurement Modes: Auto, Series, Parallel with supported parameter combinations

  • Range Modes: Auto and manual

  • Measurement Speed: 140–180 ms typical above 1 kHz; high resolution mode extends time

  • Inductance (L): 100 nH to 10 H

  • Capacitance (C): 1 pF to 100 µF

  • Resistance (R), |Z|, ESR, Reactance (X): 1 Ω to 10 MΩ

  • Conductance (G), Susceptance (B): 1 µS to 10 S

  • Dissipation Factor (D): 0.00001 to 9.9999

  • Quality Factor (Q): 0.01 to 9900

  • Phase Angle: 0 to ±180°


Key Features



  • Four-terminal pair configuration with guard terminal for enhanced accuracy

  • Automatic zero-offset to eliminate test lead and fixture residuals

  • Deviation measurement capability (absolute and percentage modes)

  • DC bias options: 0 to ±35 V (Option 001, 1 mV resolution) or 0 to ±99.9 V (Option 002, 100 mV resolution)

  • External bias support up to ±200 V

  • Compatible with HP 16047A Direct Coupled Test Fixture


Compatibility & Integration HP-IB (IEEE-488) standard interface enables integration into automated test systems and remote control via HP-IB or optional 16023B Bias Controller.

Specifications

ParameterValue
Frequency Range10 kHz to 10 MHz | Voltage / Current Range: 0 to ±35 V (Option 001)

HP / Agilent 4275A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 4275A. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 4275A faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.

HP / Agilent 4275A price

This HP / Agilent 4275A is listed at $1,259.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 4275A calibration cost

NIST-traceable calibration for the HP / Agilent 4275A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →