The Keysight/Agilent/HP 4280A is a 1 MHz capacitance meter and C-V plotter engineered for precise component and material characterization. This instrument measures capacitance and conductance as functions of applied DC bias voltage or time, eliminating the need for multiple separate instruments. The integrated design combines a precision 1 MHz C-G meter, programmable DC bias source, and accurate timing control into a single platform compatible with both floating and grounded device testing.

Technical Specifications Measurement Capability

Capacitance (C), conductance (G), or simultaneous C-G measurement

Test signal frequency: 1 MHz

Test signal level: 10 mVrms or 30 mVrms (selectable)

Capacitance range: 0.001 pF to 1.900 nF across three ranges (10 pF, 100 pF, 1 nF)

Conductance range: 0.01 µS to 12.000 mS

Measurement accuracy: 0.1% basic (conditions: D < 0.05 for C-G/C-V/G-V modes; D < 0.01 for C/G/C-t/G-t modes; C counts ≥ 1/100 of range; 23°C ±5°C; 30-minute warm-up; zero/open calibration applied) Resolution

Standard display: 4½ digits

Capacitance (standard): 0.001 pF on most sensitive range

Capacitance (Option 001 High Resolution): 5½ digits; 1 fF resolution to 190 pF, 10 fF resolution to 1.2 nF

Conductance: 10 µS maximum resolution DC Bias Source

Range: 0 V to +100 V

Resolution: 1 mV on most sensitive range

Staircase sweep: programmable start, stop, step voltage, hold time, and step delay time (up-down or single direction)

Pulse bias capability for C-t measurements Measurement Modes

C Mode: constant DC bias voltage measurement

C-V Mode: stepped DC bias voltage sweep

C-t Mode: programmed time intervals following bias pulse application

Speed selection: Fast (~70 ms C or G only; ~150 ms C and G), Medium (~100 ms), Slow (~330 ms C or G only; ~520 ms C and G) Transient Measurements

Internal pulse generator: 10 ms resolution

External pulse generator compatibility (e.g., HP 8112A): 10 µs resolution

Measurement interval (td) settable range: 10 µs minimum

Key Features

Consolidated measurement platform eliminating multi-instrument test setups

Floating and grounded device support for diverse wafer probing configurations

Programmable staircase bias sweep with independent timing parameters

Multiple measurement speed modes optimizing between measurement time and noise rejection

High-resolution option for enhanced capacitance sensitivity

Typical Applications Semiconductor characterization, material property evaluation, capacitor testing, and device reliability assessment under varying DC bias conditions.

Specifications

ParameterValue
Frequency Range1 MHz | Voltage / Current Range: 0 V to +100 V

Keysight / Agilent / HP 4280A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent / HP 4280A. Calibration covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keysight / Agilent / HP 4280A faults: GPIB interface board failure, display failure, guard terminal switch contact wear, oscillator calibration drift on older analog bridges. HP 4284A and 4285A most common faults are HPIB interface board failure and display contrast loss. The internal oscillator and vector measurement circuits are highly stable and rarely fail. Wayne Kerr and GenRad bridge instruments may develop switch contact wear on decade resistance/capacitance dials.

Keysight / Agilent / HP 4280A price

This Keysight / Agilent / HP 4280A is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent / HP 4280A calibration cost

NIST-traceable calibration for the Keysight / Agilent / HP 4280A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers impedance magnitude accuracy at 100 Hz, 1 kHz, 10 kHz, and 100 kHz, dissipation factor (D) and quality factor (Q) accuracy, phase angle accuracy, open and short compensation verification, and cable length compensation. HP/Keysight 4284A additionally verified at 1 MHz.. Turnaround is 1 to 3 business days after receipt. See full calibration details →